21
Troubleshooting
SYMPTOM
CAUSE
POSSIBLE SOLUTION
Controller not ON
Grill not powered ON
Check switch on rear of grill.
Controller not powered ON
Press power button on Kontrol Board.
Not plugged in
Plug cord into rear of grill and into wall outlet.
Circuit breaker tripped
Check wall outlet circuit breaker and reset if tripped.
Fan not ON
Pit probe has reached the set
temperature
Once the set temperature is reached, the fan will turn off. Once
the cabinet temperature falls below the set temperature, the fan
will restart. The fan will continue adjusting itself automatically
to maintain the set temperature.
Dome lid open
For safety, the fan should not stoke the fire when the lid is
open. Once the lid is shut, the fan will continue under normal
operation.
Lid switch not engaged
Your lid switch may not be making contact when your dome
is closed. If the dome is closed and the fan is not ON when it
should be, you may need a new lid switch.
ERROR – Max Temp Fault P
See below.
Slow heating
Ash buildup from previous use
Before starting your unit, remove any leftover ash from the
firebox and ash drawer that may be left from a previous cook.
Ash buildup can prevent proper charcoal ignition.
Low charcoal
Refill firebox with charcoal.
Lid open
Close lid.
Fan not on
See fan not on section.
Element not ON
AFS button not pressed
Ensure AFS button was pressed
and button is glowing red.
Element damaged
Turn off main power from grill.
Remove element from grill,
inspect for any visual damage.
Element not seated properly
Turn off main power from grill.
Remove element completely
from grill, reconnect element to
grill and be sure to fully press
element into connectors.
ERROR: Probe Fault – P
Pit probe faulty
Check to ensure pit probe is plugged into rear of the grill.
Check to ensure pit probe connection is fully seated.
Check to ensure no debris is in the pit probe jack.
Unplug the unit from the wall, wait 10seconds and reconnect.
ERROR: Probe Fault - M
Meat probe faulty
Contact Kamado Joe Customer Support.
ERROR: Startup Time-Out
Charcoal failed to ignite. Unit did
not reach 150F (65C) in under
10mins
Ensure old ash from previous use is not left in the firebox.
Ensure the AFS button was pressed and element is working.
Ensure proper vent placement for classic or automatic mode.
Ensure charcoal is not empty.
Restart
ERROR: Max Temp Fault – P
Grill overheated
Turn off grill.
Check for cause of overheat.
- Grease fire
- Fan malfunction
Eliminate cause of overheat.
Restart grill.
ERROR: Max Temp Fault - M
Meat probe temperature above
300F (149C)
Using protective gloves, remove meat probe from unit.
Unplug from controller.
Allow meat probe to cool.
Содержание KONNECTED JOE KJ15041123
Страница 3: ...3 7 10 13 16 17 5mm M6 X 25mm M6 X 16mm...
Страница 4: ...4 1 2 M6X16 X4 M6 X4 M6X16 X4 M6 X4 18 18 18 19 18 20 20 18 19 M6 X4 M6 X4...
Страница 5: ...5 3 4 M6X25 X4 M6 X4 16 22 22 21 21 M6 X4...
Страница 6: ...6 5 6 8 11 6 7 X5...
Страница 7: ...7 14 14 16 14 14 7 8 10 4 5 14...
Страница 8: ...8 9 10 1 9 10 11 12 15 1 2...
Страница 24: ...LE FRAN AIS...
Страница 40: ...ESPA OLA...
Страница 56: ...SAVE THESE INSTRUCTIONS CONSERVEZ CES INSTRUCTIONS CONSERVE ESTAS INSTRUCCIONES...