Power Supply
Cable (EU)
Cable (US)
Pin
International
Brown
Black
Live
L
Light Blue
White
Neutral
N
Yellow/Green
Green
Earth
DMX-512 connection between fixtures
The fixture is equipped with 3-pin XLR sockets for DMX input and output. The sockets are wired in parallel. Only use a shielded
twisted-pair cable designed for 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with
another.
XLR-connection
Building a serial DMX-chain
If you are using a standard DMX-controller, you can connect the DMX-output of the controller directly with the DMX-input of
the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter
cables. (DMX controller not supplied).
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect output
with the input of the next fixture until all fixtures are connected.
If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pins adapter.
The DMX output and input connectors are pass-through to maintain the DMX circuit, when power is disconnected to the unit.
Each fixture needs to have a DMX address to receive the data from the controller. The DMX address number which could be
read from rear panel of each fixture is between 000~511.