Get acquainted with this technical certificate before installing
the boiler.
1.
Technical data.
Central heating boiler "Kalvis-2-16, 2-25, 2-30, 2-40" (hereinafteer
referred to as the boiler) is used for heating of various premises where
central heating system with natural or forced circulation is arranged.
Boiler has a socket for mounting 3x1,5…3x2 kW electric heating
devices (with 2“ thread) with temperature control and emergency
thermostats or without them (devices not included).
1 fig.
1.Air supply damper. 2.Service doors. 3.Cast iron doors. 4.smoke exhaust
channel. 5.Fuel loadinjg doors. 6.Thermometer. 7.Draught adjuster. 8.Top loading
cover. 9.Electric heating device socket. 10.Smoke exhaust damper. 11.Service
cover. 12.Chamotte brick. 13.Hot water tube. 14.Ignition damper. 15.Draught
damper. 16.Turbulators. 17.Screen (only for Kalvis-2-16). 18.Secondary air
openings. 19.Combustion chamber. 20.Return water tube. 21.Drainage tube.
22.Ash removal cover. 23.Fire grate mover. 24.Movable fire grate.
Measures designated by letters are included in „main technical data“ table.
KALVIS-2-16, 2-25, 2-30, 2-40 en 2009.05.18