KALVIS-2-16, 2-25, 2-30, 2-40  en       2009.05.18

 

 

 

shoelds. Front side of the boiler has draught adjuster (p.7), which controls 
air supply damper (p.1), thermometer (p.6), doors (p.2), behind which there 
are servoce doors (p.3). Loading chamber is closed with doors (p.5).  In the 
boielr there is a smoke exhaust damper (p.10) and ignition damper (p.14), 
which allows a direct smoke flow into the chimney, ignition damper is used 
for fuel ingition and loading extra fuel; also the fire grate (p.24), secondary 
air opening (p.18). Combustion chamber has chamotte bricks (p.19) that 
maintain high temperature of combustion. Beneath the shields there is a 
servoce cover (p.11) for cleaning the internal surfaces fo the boiler. 

On the sides of the boiler there are secandary air controlling dampers.  
Rear side of the boiler has drainage tube (p.21), return (p.20) and hot 

water (p.13) tubers, smoke pipe with draught damper (p.15). 

Boiler heat exchanger (except Kalvis-2-16) has turbulators (p.16) that 

ensure a better heat transfer.  

If there is an insufficient draught it is recommended to remove 

turbulators. 

Electric heating devices are automatically switched on when boiler runs 

out of fuel and temperature falls beneath the preset waiting mode  
tmeperature.

 

3.

 

Transportation and storage. 

Transport boilers only in vertical position by all types of covered 

transport. Transporting by not covered transport is possible only when the  
weather is dry. Use additional protection means to protect boilers against 
fall downing and scratching. Striking, turning over or throwing boilers 
during loading, unloading or transportation time is strictly prohibited. 

The boilers are to be stored in the dry rooms, where is no vapour of 

chemicaly active materials. 

4.

 

Mounting 

Boiler has to be installed in the premises that meet, RSN-159-95 and  

RPST-01-97 requirements or according to similar national regulations. 

, RSN-159-95 and 

 

RPST-01-97 requirements or according to similar national regulations. 

It is recommended to have mounted a smoke collecting cobver 

above boiler. Boiler should be mounted vertically, or with forward 
inclination, which would not exceed 1 degree.  

 

4.1 

Fire precautions:

 

*

 

Boiler should be placed on the incombustible material; 

Содержание K-2-16

Страница 1: ...CENTRAL HEATING BOILER ON SOLID FUEL KALVIS 2 16 2 25 2 30 2 40 USERS INSTALLATION AND OPERATION MANUAL CERTIFICATE NO SPSC 5199...

Страница 2: ...2...

Страница 3: ...without them devices not included 1 fig 1 Air supply damper 2 Service doors 3 Cast iron doors 4 smoke exhaust channel 5 Fuel loadinjg doors 6 Thermometer 7 Draught adjuster 8 Top loading cover 9 Elec...

Страница 4: ...mm 290 x 290 290 x 290 290 x 390 290 x 490 Overall dimensions mm Hg H Bg B Lg L 1380 1300 760 600 1060 800 1500 1420 590 490 1220 960 1500 1420 690 590 1230 970 1500 1420 790 690 1230 970 Branching d...

Страница 5: ...re is an insufficient draught it is recommended to remove turbulators Electric heating devices are automatically switched on when boiler runs out of fuel and temperature falls beneath the preset waiti...

Страница 6: ...4 2 Requirements for chimney Chimney design and boiler connections into it are shown on the fig 2 and 3 Boiler sold Company Sales date Address Phone Boiler mounted Company Address Phone Foreman name l...

Страница 7: ...al elbow it s cross section has to be not less than that of the boiler smoke pipe and bending radii not less than 100mm Pipe from the smoke pipe to chimney has to be not longer than 1 5 m and lean upw...

Страница 8: ...value is similar 1 kg of coal gives 2 3 times more heat than 1 kg of wood Combustion of 1 kg of wood requires 4 5 m3 of air coal around 10 m3 The more ash is left the worse fuel is Energy radiation f...

Страница 9: ...se hot or return water valves when boiler is operated Store dry fuels or other combustible materials close to or on top of the boiler Store fuel closer than 500 mm to boiler Ignition fuel with combust...

Страница 10: ...l ventilated Recommenmded fuel humidity not greater than15 20 Attention If the boiler combusts humid wood or saw dust condensate will form acids which will shorten the life span of the boiler several...

Страница 11: ...waste and ignite it In case of coal combustion 5 10 kg of firewood should be covered by a 10 cm layer of coal Secondary air dampers p 18 should be closed Dampers are operated when tmeperature in the b...

Страница 12: ...uld be removed It is necessary to mount the protection valve that keeps the operating pressure in the system not greater than 0 15 MPa 1 5 kgf cm2 Notice To avoid appearance of the condensate which ma...