The fire goes out or 
the stove stops auto-
matically

1. The pellet tank is empty
2. No power
3. Pellets not being fed
4. Excessive deposit of ashes in 
the grate
5. Intervention probe temperature 
safety of the pellet
6. Cochlea blocked by dirt
7. The door is not closed prop-
erly or gaskets worn
8. Pellet inadequate

9. Low pellet

10. Chimney or drain clogged 
with nests or foreign bodies
11. Pressure switch cuts
12. Smoke extraction motor 

failure

13. Alarm active

1. Fill the tank with pellets
2. Check plug and presence electricity
3. Fill the tank with pellets
4. Clean the brazier
5. Let the stove cool down completely, reset the 
manual reset and restart the stove. If the problem 
persists, contact your authorized service representa-

tive

6. Pull the plug, empty the tank, remove any foreign 

objects

7. Close the door or replace the gaskets with original
8. Change the type of pellet recommended by the 

manufacturer. 

Sometimes, depending on the type, 

the stage of adjustment of the parameters need 
to vary the level relating to the loading of pellets

9. Increase the level in the parameter for the pel-
let feed. T

o check the flow of fuel from technical 

authorized

10. Eliminate all foreign matter from the chimney 
Clean the smoke duct. Perform periodic cleaning.

11. Verify potential smoke duct is blocked and if 
the pressure switch is working properly
12. Check and replace the motor if necessary

13. See paragraph alarms

The air fan convention 
(ambient air) never 

stops

1. Temperature sensor tempera-

ture control defective or broken

2. Smoke probe fails

1. Check the operation of the sensor and replace if 
necessary
2. Replace smoke probe

The stove does not 
light.

1. Lack of electricity
2. Probe pellets in bulk
3. Fuse blown
4. Pressure switch broken (lock-
out indicated)
5. Smoke outlet or duct clogged

1. Check that the electrical outlet is plugged in and 
the power switch to "I"
2. Lockout by resetting the rear thermostat, 

replace 

the thermostat

 if it happens again

3. Replace the fuse

4. Replace the pressure

5. Clean the smoke outlet and / or smoke duct

Содержание Denia 14

Страница 1: ...INSTALLER USER MANUAL For Denia 14 14D Mia 16 16D...

Страница 2: ...e door handle sides can reach high temperatures There fore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly must be p...

Страница 3: ...for accidents deriving from the partial or total lack of observance of the instructions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by t...

Страница 4: ...ance Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes hangers and suchlike must be kept a suitable distance from the stove Risk of fire Carefully explain...

Страница 5: ...its weight If walls are flammable maintain a minimum distance of 20 cm at the rear A of 30 cm at the side B and 100 cm at the front If the room contains objects which are believed to be particularly...

Страница 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Страница 7: ...of type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself The device should not be installed in th...

Страница 8: ...nothermostat 1 2 3 SET 4 5 6 This signalises that the automatic single or daily switching on or off of the stove is on The automatic programming can be set only using the remote control Resistance ind...

Страница 9: ...8 88 175 495 50 Air Intake 8 0 S m o k e O u t l e t 80 Channeling If Any 1020 1084 269 296 457 30 Theremotecontrol Fig 3 usedtoadjustwatertemperature power and the on off functions for the pellet sto...

Страница 10: ...00 0 5 0 4 400 120 2 1 5 4000 2000 1 1 2 2000 1000 DA A 2 5 3 5 OLTRE CAMPO TOLLERANZA LUNGH LATO CORTO 3 FINO A 10 2 DA 10 A 50 1 DA 50 A 150 30 OLTRE 150 A A A A A DA DA DA DA DA 36030 San Vito di L...

Страница 11: ...230 230 Nominal frequency Hz 50 50 Power consumption max W 400 400 Stove weight Kg 135 140 140 145 N Test Report K19052016T1 The pellets are cylinders of compressed wood produced from sawdust and wood...

Страница 12: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Страница 13: ...buttons 1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the stove Once the thermostat is activated deactivated press button 4 OFF...

Страница 14: ...og 2 on off 16 thursday prog 2 on off 17 friday prog 2 on off 18 saturday prog 2 on off 19 sunday prog 2 on off 20 start program 3 hour 21 stop program 3 hour 22 monday progr 3 on off 23 tuesday progr...

Страница 15: ...programmes PROGRAMME 1 menu level selection meaning possible values 02 03 02 START PROGRAM 1 activation time time OFF 02 03 03 STOP PROGRAM 1 shut off time time OFF 02 03 04 MONDAY PROGRAM 1 reference...

Страница 16: ...5 6 1 and 1 2 3 SET 4 5 6 2 Stand by mode This mode allows the automatic shutdown of the stove once it reaches the temperature set on SET When this happens the stove will wait a few minutes factory se...

Страница 17: ...SET key to access the menu to set the speed of your funnel fans 3 Set the speed using the buttons 1 and 2 With key 1 you set the speed of the right fan with key 2 you set the speed of the left fan 4 T...

Страница 18: ...tilator gear motor and room ventilator are on during this phase 14 35 21 C P 2 LOAD pellet 14 35 21 C P 2 FLAME LIGHT 15 18 21 C P 3 WORK 5 16 40 22 C P 2 CLEANING FIRE POT Regular checks should be ca...

Страница 19: ...irty If the glass is broken do not attempt to light the stove Cleaning the ceramic covering if supplied The ceramic tiling must be cleaned with a soft dry cloth before using a damp cloth Use only neut...

Страница 20: ...ttom of the chamber combusione and the compartment that is located below the ash box photo 8 Also clean the brazier and the ash box After completing the cleaning replace the refractory its attachment...

Страница 21: ...y per formance It is therefore necessary to clean the fans at least once a year Since said operation requires dismantling several parts of the stove have the fans cleaned only by our Technical As sist...

Страница 22: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Страница 23: ...ion or shuts the stove when the flue gas temperature drops below the preset value Electrical safety the stove is protected against violent surg es of current ex lightnings by the main fuse 4 A which i...

Страница 24: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Страница 25: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Страница 26: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Страница 27: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Страница 28: ...55 GB NOTES...

Страница 29: ...56 GB NOTES...

Отзывы: