67
GB
Scheme 03:
the boiler is connected to a domestic hot w
ater tank and to the heating circuit.
The boiler is switched off when the probe is satisfied.
The boiler is switched on when the probe detects a lower temper
ature
to SET
ACS - ΔT (ΔT settable by technical par
ameters).
a)
To set the w
ater temper
ature in the boiler press the
. k
ey
. Increase or decrease the degrees with the k
eys
and
.
b)
To set the desired temper
ature in the room (using the probe on the board) press the k
ey
.
Increase or decrease degrees with the
and
k
eys
c)
To set the work power
, press the
k
ey and adjust it with the
and
k
eys
d)
To adjust the working power
, the desired temper
ature inside the DHW tank,
press the button
. Increase or decrease the desired degrees with the
and
.
The rinsing from the stand-by state occurs automatically when a heat increase is required to return to satisfy the chosen stand-by condition (when this is set to ON)
or when there is a risk of hot w
ater inside the puffer
.
1 =
Valve motorization
2 =
External thermostat On / OFF for
stand-by type 3 (optional)
3 =
NTC5K probe on DHW tank
2
1
3
the scheme is indicative and w
ants to
demonstr
ate only the components that can be
managed by the boiler
. Any relay pumps must be
controlled separ
ately from the boiler
Содержание Alessia