75
GB
Alarm signals
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
Regular checks should be carried out by the user, who should only contact the Authorized
Assistance Center if no solution is found.
Display
Superiore
Lower
Display
Kind of failure
Solution
ALAR
NO
LIGHTIN-
The boiler cannot start up
This is the first light-up
Fill in the tank with pellets
Start up again
ALAR
NO
FIRE
The pellet boiler switched off while
working
Fill in the tank with pellets
ALAR
SOND
FUMI
The smokes sensor is broken or not
connected to the pcb
Contact an Authorized Assistance
Center
ALAR
HOT
H2O
The water temperature exceeds 90°C.
The circulating pump is blocked or there
is
no water in the hydraulic system
Check the power supply on the pump.
Check limestone does not block the
pump impeller
ALAR
SOND
H2O
The water sensor is not connected
There is a short circuit on the water
sensor
Check the water sensor is connected
Contact an Authorized Assistance
Center
ALAR
HOT
TEMP
The smokes temperature exceeds
280°C
Smokes sensor failure
Contact an Authorized Assistance
Center
COOL
FIRE
There is no power supply
As soon as the power supply is back,
the boiler starts a cooling cycle. After
completing the
cycle it starts working automatically
ALAR
FAN
FAIL
Smokes extractor blocked or broken
Contact an Authorized Assistance
Center
ALAR
DEP
FAIL
Obstructed flue
Clean the flue or check there are no ob-
structed grids near the smokes exhaust
ALAR
SIC
FAIL
Pellets tank overheating
Re-set the safety thermostat for pellets
on the back of the boiler. If the problem
occurs again, contact an Authorized As-
sistance Center
ALAR
PRESS
The system pressure does not reach 0,5
bar or exceeds 2,3 bar
Reduce the system pressure
Charge the system
ALAR
NO NETWORK
Absence power supply
The return of electricity to restart the
stove
SERV
The boiler has worked for 1300 hours.
Supplementary maintenance required