background image

 

 

 

Captis Cloud Configuration Guide  

 

Page | 5  

3.3  Secure the pins 

 

Please ensure that care is taken to select the correct terminal for each pin as the 

connector is not suitable for pin removal. As such, there is no recommended practice 

for pin removal. 

 

 

After all of the cable conductors have been successfully fastened to the crimps, the 
amphenol pins may be inserted into the pin receptacles.  

Insert each pin into each receptacle until you hear a small click. 

Attempt to remove each pin with light force after this click to confirm they are securely 
fastened.  

If you do make an error, please call your distributor and request a replacement 
connector kit and replace the connector assembly. It is recommended that spare 
connector kits are carried by Captis installers to prevent multiple site visits in the event 
of a mistake. 

3.4  Fasten the Connector 

Install the Clamp Ring to the housing-with-contacts by screwing. Make sure to apply 
the correct tortional force.  

Clamping ring torque: 6 ~ 8kgf.cm(0.58 ~ 0.78 Nm) 

Figure 2 

Ensure that the clamp seal aligns with the clamp ring surface, as seen below: 

 

Figure 3 

Отзывы: