Captis Cloud Configuration Guide
Page | 5
3.3 Secure the pins
Please ensure that care is taken to select the correct terminal for each pin as the
connector is not suitable for pin removal. As such, there is no recommended practice
for pin removal.
After all of the cable conductors have been successfully fastened to the crimps, the
amphenol pins may be inserted into the pin receptacles.
Insert each pin into each receptacle until you hear a small click.
Attempt to remove each pin with light force after this click to confirm they are securely
fastened.
If you do make an error, please call your distributor and request a replacement
connector kit and replace the connector assembly. It is recommended that spare
connector kits are carried by Captis installers to prevent multiple site visits in the event
of a mistake.
3.4 Fasten the Connector
Install the Clamp Ring to the housing-with-contacts by screwing. Make sure to apply
the correct tortional force.
Clamping ring torque: 6 ~ 8kgf.cm(0.58 ~ 0.78 Nm)
Figure 2
Ensure that the clamp seal aligns with the clamp ring surface, as seen below:
Figure 3