Captis Cloud Configuration Guide
Page | 3
2.2 Compatibility
It is important to ensure that the sensor being terminated is compatible with the
selected Captis device. Please find compatibility details below noting that all approved
sensors
2
may be connected and logged at once. However, any more than 2 x digital
inputs may adversely affect battery longevity.
DEVICE
SENSOR INPUTS
Pulse 1.2 and Pulse Lite 1.0
•
2 x Digital Inputs
Multi 1.2 and Recharge 1.2
•
2 x Digital Inputs
•
1 x 4-20mA Analogue Input
•
1 x 0-10VDC Analogue Input
•
1 x Serial Input (Modbus RS232/RS485)
•
1 x 1-Wire Input
Table 2
3 Terminating
When terminating cable into the Captis
’ Amphenol connector please follow these steps:
1. Prepare the cable
2. Crimp the pins
3. Secure the pins
4. Fasten the connector
3.1 Prepare the Cable
The following diagrams outline how to prepare the sensor cable for termination. These
guidelines support the manufacturers specification.
Table 3
Strip Insulation Length (A)
Strip Jack Length (B)
3.5mm
– 4mm
16mm
– 18mm
2
Please contact
to ensure the selected sensor is compatible with the selected Captis device.