14
The risk of discoloration
CAREFUL!
After the convection system of the fireplace has
been heated, air particles, cigarette smoke, candles and oil lamps can cause
discoloration of walls and ceilings. Ensure sufficient ventilation in the room in
which the fireplace is installed.
CAREFUL!
Applying tape to the fireplace is at your own risk, paint damage caused by
taping is outside the manufacturer's warranty.
2.3
Three safety measures for the gas fire
The flame is detected due to electronic ionization measurement. If the gas
fire does not detect a flame during the start-up phase, the gas supply is
interrupted for one minute. A new ignition attempt follows automatically. To
interrupt automatic ignition attempts immediately; Press the on/off button
(max 2 sec.) to switch the fire off immediately.
A 24-hour security system
If no flame is detected after three automatic ignition attempts (for gas types
G20, G25), a blocking occurs. For gas types G30 and G31, this blocking occurs
after one ignition attempt. This lockout can be manually unlocked twice with
the remote control. If no flame is detected after these two manual releases, a
24-hour lock-out will follow. You can then not use the gas fire for 24 hours.
Pressure relief device
The gas fire is equipped with an overpressure safety device to minimise risks.
Should an explosive ignition occur, the top window will open forward to reduce
pressure.
Содержание Gi105/59F
Страница 1: ...User Instructions BALANCED FLUE GAS SYSTEMS...
Страница 2: ......
Страница 4: ......
Страница 44: ...44...
Страница 45: ...45...
Страница 46: ...46...
Страница 47: ...47...
Страница 48: ...48...
Страница 49: ...49...
Страница 50: ...50...
Страница 51: ...51...
Страница 52: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire com KALFIRE COM...