11/ Troubleshooting
11.1/ Abnormal heart rate
You have noticed large fluctuations in your heart rate.
Check that the strap is in place and the sensors have been moistened (diagram 1, page 1).
Interferences in the environment due to electromagnetic disturbance can make heartbeat readings temporarily unstable or
inaccurate. This is nearly always due to being in close proximity to high voltage lines, overhead lines, traffic lights, televisions, car
engines, some motorised sporting equipment, mobile phones, computer screens, microwave ovens or when you are going through
electrical security gates.
There are other causes for altered heartbeat readings:
- Clothes that chafe on the strap or are full of static electricity.
- Very hairy chests.
- Dirt on the strap.
If heartbeat readings are unstable, first check that none of the causes above are responsible for the problem.
11.2/ Detecting the strap
If the
does not flash:
- Move the strap closer to the watch.
- Adjust the position of the strap by moistening the sensors further.
- Check that the batteries are working, especially in the strap.
- In
CARDIO
or
TIMER mode
Synchronise the watch by holding down the
MODE button
. (see Chapter 5.1)
If the link with the strap is broken temporarily, a heart rate of 0 is displayed on the main line.
If the link is broken for more than five minutes, the display changes to ---. In order to reactivate the signal
search, press down for 3 seconds on
MODE
. The search will begin again. (see Chapter 5.1).
11.3/ Advice on use for people fitted with a coronary stent
A coronary stent can affect the transmission of the heartbeat from the strap to the watch, we advise you wear the strap above
pectoral muscles.
11.4/ Abnormal flashing of the display or malfunctions.
The battery is probably flat, it must be changed.
12/ Technical characteristics
13/ Limited warranty
OXYLANE guarantees to the initial purchaser of this item that it is exempt from all faults linked to materials and manufacture. This
product is guaranteed for two years from the purchase date. Please keep your receipt as proof of purchase.
The warranty does not cover:
• damage resulting from misuse, from a failure to respect the precautions for use, from accidents, from improper maintenance or
from commercial use of the product.
• damage resulting from repairs carried out by persons not authorised by OXYLANE.
• batteries or casings which are cracked or broken or which show signs of impact.
• During the warranty period, the item will either be repaired free of charge by an authorised repair service or replaced free of charge
(depending on the distributor) .
• The warranty does not cover the elastic strap, which is subject to wear and tear.
Watches
Heart rate
monitor strap
Waterproof design
5 ATM
1 ATM
Range according to the sports use of the
product (with the strap)
1 hour/week
20 months
32 months
4 hours/week
15 months
10 months
Memory
5 sessions, 50 laps
(CARDIO)
or 25
repetitions
(TIMER) per session
Bracket of authorised values
Heart rate target
zone
30 - 230 beats per minute
Heart rate
30 - 230 beats per minute
Communication protocols
5.3 Khz coded
5.3 Khz coded
Transmission reach:
1 m in use 0.5 m in detection
1 m in use 0.5 m in
detection
Functional temperatures:
-10°C to 50°C
-10°C to 50°C
Batteries
CR 2032
CR 2032
Weight
48 g.