background image

LIGHTING CARE INFORMATION

E v e r y   A L L E G R I ®   f i x t u r e   i s   o f   h e i r l o o m   q u a l i t y   a n d   w i l l   l a s t   f o r   g e n e r a t i o n s .   T o   e n s u r e   i t   r e t a i n s   i t s   b r i l l i a n c e   a n d  

splendor for years to come, proper care and regular cleaning are necessary. 

It is recommended that ALLEGRI® fixture, and particularly their crystal trim, be lightly dusted with a feather or lambs wool 

d u s t e r ,   o r   s o f t   b r u s h   e v e r y   t w o   m o n t h s ,   o r   w h e n e v e r   i t   a p p e a r s   d u l l   o r   d u s t y .   A   t h o r o u g h   c l e a n i n g   s h o u l d   b e  

completed every six months. 

Before cleaning an ALLEGRI® fixture, first locate the fixture's trim diagram. This will assist in replacing the crystal trim in 

its proper location after cleaning. Should a replacement trim diagram be required, please call 

866-820-2665 to speak with an ALLEGRI® customer service representative, who can provide a new diagram. 

ALLEGRI ®   recommends  several  dif f erent   cleaning  met hods,   depending  on  t he  t ype  of   f ixt ure.   Some  f ixt ures  can  be

cleaned with limited removal of crystal, while others must be completely untrimmed.

Place a soft towel or blanket directly beneath the fixture to limit the damage to both the crystal and the surface below the 

fixture, should a piece of crystal be dislodged during the cleaning process. Extreme care must be taken around any

electrical fixture. For personal safety and the safety of the fixture, be sure that the fixture has been turned off. Never rotate or 

spin the fixture as this can cause the fixture to lose support and fall. Instead, move around the fixture while cleaning. 

White Glove Method

Prepare a cleaning solution of one part isopropyl alcohol to three parts distilled water and place in a clean spray bottle. 

Do not use packaged cleaning fluids, as many of these contain ammonia, which may degrade the finish of the fixture and 

the quality of the crystal.

Wearing white cotton gloves, spray one glove with the solution and keep one dry. Gently polish each crystal with the damp 

g l o v e   a n d   i m m e d i a t e l y   w i p e   i t   w i t h   t h e   d r y   g l o v e .   D o   n o t   t u g   o r   p u l l   o n   t h e   c r y s t a l ,   a s   t h i s   m a y   c a u s e   t h e  

connectors to chip or crack the crystal, or dislodge it from the fixture. 

Warning: To reduce the risk of personal injury due to fire and/or electric shock, never spray solution at or near the fixture.

Crystal Removal Method

Gently remove trim and hand-wash the crystal in lukewarm water using a mild detergent. Rinse in clean water and dry with a 

s o f t   c l e a n   c l o t h .   D o   n o t   s o a k   f i n i s h e d   c r y s t a l   s u c h   a s   S W A R O V S K I   E L E M E N T S   C o l o r s :   T e a k ,   G o l d e n   S h a d o w   o r    

Silver Shade, for extended periods, as this may degrade the crystal's finish. 

With the fixture untrimmed and turned off, wipe the frame, including the light bulbs once they are completely cool, with a soft 

cloth. 

Wearing white gloves, finger-cots or using a soft clean cloth, gently replace the trim as directed in the trim diagram. 

WWW.ALLEGRICRYSTAL.COM

866.820.2665

P6

Содержание ALLEGRI 027753

Страница 1: ... a combination of traditional manufacturing such as sand casting hand forging and technology driven techniques including laser cutting Enclosed are detailed instructions on how to properly install your fixture Please read all instructions carefully If you need further assistance please contact the dealer from which you purchased this product or call 866 820 2665 to speak with an ALLEGRI customer s...

Страница 2: ... and cleaning of Glass and or Crystal Components v This product is rated 110 130V 60HZ bulb 40W Maximum v Save these instructions for future reference WARNING The electricity must be turned off at the main fuse box or circuit breaker before installing this fixture Turning the power off using the light switch may not be sufficient to prevent electrical shock ALLEGRI will not be liable for injury or...

Страница 3: ... Solid Nipple from top side of main ceiling beam 5 Screw Collar Loop to Nipple as shown raise Canopy flat to ceiling and secure it with Collar Loop Ring 6 Hang Chain to Collar Loop with the Easy Link Proceed to fixture frame assembly Step 1 Solid Nipple Hex nut and washer Screws Outlet box by others Canopy Collar loop Collar loop ring Easy link 2pcs Chain WARNING Electrical Danger Turn Power Off A...

Страница 4: ...rew to part 1 22 i Check the installation and attach bulb into lamp holder 1 Mounting ring P4 7 Metal lathe A 21 Arm A 4 Round metal sheet A 22 Main body A 6 Bronze column A 16 Thread Rod A 5 Crystal tray A 8 Copper plate A 9 Crystal tray B 10 Round tube A 11 Crystal tray C 12 Copper plate B 17 Crystal Column A 24 Copper plate D 40 Cannula A 39 Crystal tray 43 Metal lathe E 38 Rolling plate A Stee...

Страница 5: ...0 Watts Recommended 40 Watts Max Bulb not included CRYSTAL DRESSING INSTRUCTION WWW ALLEGRICRYSTAL COM 866 820 2665 MODEL 027753 010 FR001 WARNING Electrical Danger Turn Power Off All electrical components must be installed by a licensed electrician in accordance with the National Electric code and the appropriate local electrical codes c R Code Qty 1 B A P5 B 42 A A B 1080 14 2pcs 82931 76 1pcs 1...

Страница 6: ...re that the fixture has been turned off Never rotate or spin the fixture as this can cause the fixture to lose support and fall Instead move around the fixture while cleaning White Glove Method Prepare a cleaning solution of one part isopropyl alcohol to three parts distilled water and place in a clean spray bottle Do not use packaged cleaning fluids as many of these contain ammonia which may degr...

Отзывы: