voltage by tampering with the safety micro switches or main switch.
G. Take the necessary precautions to avoid the machine being started by other people
during loading, adjustment, piece changing or cleaning.
9. MAINTENANCE AND REPAIRS
9.1GENERAL SAFETY MEASURES
A. Lockable main switch. Use the padlock in the event of machine failure or replacement
of the band. The padlock key should be entrusted to a responsible person.
B. Before carrying out any work on electrical equipment, remove the power supply plug
from the control pane (disconnect voltage).
C. Only use cables to supply power, which have a cross-section suited to the power of
the machine.
D. Opening key. The keys of the machine should be dept by authorized personnel. Do
not leave the keys for doors that provide access to the hydraulic or electrical parts or
keys to lockable switches in easy of reach of unauthorized personnel.
E. Repairs should only be carried out by authorized personnel. Only spare parts made
by the original manufacturer should be used, otherwise these could cause damage or
injury.
9.2 ROUTINE CHECKS AND MAINTENANCE
FREQUENCY
(working hours)
OPERATION
100 hours
Adjustment blade guide bearings
1000
Lubrication of mobile parts in the piece locking vice (GREASE
AGIP MU 2)
50
Cleaning of the coolant tank and filter check
If necessary
Check functioning of bench lever
9.3 DESCRIPTION OF ROUTINE MAINTENANCE
A. Adjustment of the blade guide bearings
Loosen the screws 69, rotate the cams 72, so that the blade guide bushings vertically
position the blade in axis (DRAW.3 ENCL.2). Loosen the lock nuts 31 and tighten the
dowels 67 until the blade secured. Loosen the dowels 67 slightly (about 1/10 of a turn)
Содержание BS-126G