Outdoor Unit 

Installation

Outdoor Unit Installation

Outdoor Unit Installation Instructions

Step 1: Select installation location. 

The outdoor unit should be installed in the 

location that meets the following requirements: 

 

Place the outdoor unit as close to the indoor 

unit as possible. 

 

Ensure that there is enough room for 

installation and maintenance. 

 

The air inlet and outlet must not be 

obstructed or exposed to strong wind. 

 

Ensure the location of the unit will not be 

subject to snowdrifts, accumulation of leaves 

or other seasonal debris. If possible, provide 

an awning for the unit. Ensure the awning 

does not obstruct airflow.   

 

The installation area must be dry and well 

ventilated.

 

There must be enough room to install the 

connecting pipes and cables and to access 

them for maintenance. 

 

The area must be free of combustible gases 

and chemicals.  

 

The pipe length between the outdoor and 

indoor unit may not exceed the maximum 

allowable pipe length. 

 

If possible, 

DO NOT 

install the unit where it 

is exposed to direct sunlight.

 

If possible, make sure the unit is located far 

away from your neighbors’ property so that 

the noise from the unit will not disturb them.  

 

If the location is exposed to strong winds (for 

example: near a seaside), the unit must be 

placed against the wall to shelter it from the 

wind. If necessary, use an awning. 

(See Fig. 5.1 & 5.2)   

 

Install the indoor and outdoor units, cables 

and wires at least 1 meter from televisions or 

radios to prevent static or image distortion. 

Depending on the radio waves, a 1 meter 

distance may not be enough to eliminate all 

interference.    

Strong wind

Strong wind

                       

Strong wind

   

Fig. 5.1

  

Fig. 5.2

Step 2: Install outdoor unit.

Fix the outdoor unit with anchor bolts (M10)

>60cm / 23.6”

Fix with bolts 

 CAUTION

• 

Be sure to remove any obstacles that 

may block air circulation. 

 

• 

Make sure you refer to Length 

Specifications to ensure there is 

enough room for installation and 

maintenance.   

Fig. 5.3

5

Содержание KOD30U-36HFN32X

Страница 1: ...ion Manual Ceiling Floor Type IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference KUE 18HRF32 KUE...

Страница 2: ...door Unit Installation 11 a Outdoor Unit Installation Instructions 14 b Outdoor Unit Types and Specifications 15 c Notes on Drilling Hole in Wall 16 Drainpipe Installation 17 Table of Contents Install...

Страница 3: ...ructions 21 Wiring 23 a Outdoor Unit Wiring 23 b Indoor Unit Wiring 24 c Power Specifications 25 Air Evacuation 27 a Evacuation Instructions 27 b Note on Adding Refrigerant 28 Test Run 29 30 MC MC 7 8...

Страница 4: ...let pipe sheath some models 1 Outlet pipe clasp some models 1 Drain joint some models 1 Seal ring some models 1 EMC Magnetic Ring some models Remote controller Its Frame some models Magnetic ring wrap...

Страница 5: ...not be made by children without supervision Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Only trained and certified technicians sh...

Страница 6: ...ervicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of t...

Страница 7: ...it is checked for leaks proper record keeping of all checks is strongly recommended CAUTION CAUTION CAUTION This symbol shows that a service personnel should be handling this equipment with reference...

Страница 8: ...2 3 4 5 MC MC 6 7 Install the indoor unit Page 10 INSTALLATION ORDER Install the outdoor unit Page 14 Install the drainpipe Page 17 Evacuate the refrigeration system Page 27 Connect the wires Page 24...

Страница 9: ...e unit may fall and cause personal injury unit and property damage or death DO NOT install the indoor unit in a bathroom or laundry room as excessive moisture can short the unit and corrode the wiring...

Страница 10: ...can fill the entire room There is no direct radiation from heaters CAUTION DO NOT install the unit in the following Areas with oil drilling or fracking Coastal areas with high salt content in the air...

Страница 11: ...ble 4 1 Indoor parts installation size MODEL Btu h Length of A mm inch Length of B mm inch 18K 24K 1068 42 675 26 6 30K 48K 1285 50 6 675 26 6 36K 48K 1650 65 675 26 6 60K 1650 65 675 26 6 Length of C...

Страница 12: ...ing after installing the main body When choosing where to start the determine the direction of the pipes to be drawn out In cases where there is a ceiling position the refrigerant pipes drain pipes an...

Страница 13: ...inimum drain tilt is 1 100 or more 10 Mount the indoor unit onto the hanging screw bolts with a block Position the indoor unit on a flat level by using a level to prevent leaks See Fig 4 11 Wall Mount...

Страница 14: ...length between the outdoor and indoor unit may not exceed the maximum allowable pipe length If possible DO NOT install the unit where it is exposed to direct sunlight If possible make sure the unit i...

Страница 15: ...to Fig 5 7 5 8 5 9 and Table 5 2 Fig 5 7 Fig 5 8 Fig 5 9 Fig 5 6 Fig 5 5 A B D W H W H Fig 5 4 Outdoor Unit Dimensions W x H x D Mounting Dimensions Distance A Distance B 760x590x285 29 9x23 2x11 2 5...

Страница 16: ...mponents 3 Place the protective wall cuff in the hole This protects the edges of the hole and will help seal it when you finish the installation process Fig 5 11 L H 300 cm 118 or more A 60 cm 23 6 or...

Страница 17: ...el switch In HEAT mode the outdoor unit will discharge water Ensure that the drain hose is placed in an appropriate area to avoid water damage and slippage due to frozen drain water DO NOT pull the dr...

Страница 18: ...inish the installation process Wall Indoor Outdoor 12mm 0 5 inch Fig 6 4 NOTE When drilling the hole in the wall make sure to avoid wires plumbing and other sensitive components 4 Pass the drain hose...

Страница 19: ...rk Notes On Pipe Length and Elevation Ensure that the length of the refrigerant pipe the number of bends and the drop height between the indoor and outdoor units meets the requirements shown in Table...

Страница 20: ...raps in the rising gas piping can prevent this CAUTION The indoor unit is installed higher than the outdoor unit If the outdoor unit is installed higher than the indoor unit It is recommended that ver...

Страница 21: ...ipe while cutting Be extra careful not to damage dent or deform the pipe while cutting This will drastically reduce the heating efficiency of the unit 1 Make sure that the pipe is cut at a perfect 90...

Страница 22: ...3 9 Fig 7 11 6 After connecting the copper pipes to the indoor unit wrap the power cable signal cable and the piping together with binding tape NOTE DO NOT intertwine signal cable with other wires Wh...

Страница 23: ...Ensure that main supply connection is made through a switch that disconnects all poles with contact gap of a least 3mm 0 118 DO NOT modify the length of the power cord or use an extension cord CAUTIO...

Страница 24: ...he electric control box Indoor Unit Wiring 1 Prepare the cable for connection a Using wire strippers strip the rubber jacket from both ends of a signal cable to reveal about 15cm 5 9 of the wires insi...

Страница 25: ...19K 24K 25K 36K 37K 48K 49K 60K POWER PHASE 1 Phase 1 Phase 1 Phase 1 Phase 1 Phase FREQUENCY AND VOLT 208 240V 208 240V 208 240V 208 240V 208 240V CIRCUIT BREAKER FUSE A 25 20 32 25 50 40 70 55 70 60...

Страница 26: ...20V 208 240V 208 240V CIRCUIT BREAKER FUSE A 25 20 32 25 32 25 45 35 MODEL Btu h 36K 37K 60K 36K 37K 60K POWER indoor PHASE 1 Phase 1 Phase 1 Phase 1 Phase FREQUENCY AND VOLT 220 240V 220 240V 220 240...

Страница 27: ...ow Pressure side of the manifold gauge Keep the High Pressure side closed 4 Turn on the vacuum pump to evacuate the system 5 Run the vacuum for at least 15 minutes or until the Compound Meter reads 76...

Страница 28: ...as the standard pipe length is 5m 16 The additional refrigerant to be charged can be calculated using the following formula Liquid Side Diameter R32 Total pipe length standard pipe length x 12g 0 13oZ...

Страница 29: ...ed correctly d Ensure the indicators on the remote control and the display panel on the indoor unit work properly e Ensure the manual buttons on the indoor unit works properly f Check to see that the...

Страница 30: ...is appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old applia...

Страница 31: ...ossible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can possibly...

Страница 32: ...ties are advised Initial safety checks shall include that capacitors are discharged this shall be done in a safe manner to avoid possibility of sparking that there no live electrical components and wi...

Страница 33: ...shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum This proc...

Страница 34: ...the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimize...

Страница 35: ...in satisfactory working order has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in...

Страница 36: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Page 36 QSBPDLI 051AEN R32 E...

Отзывы: