55
Heating
R44
Max. Limit Target Water Temp. at High AT in
Heating
20~85
℃
40
℃
20~60
℃
R45
AT to Start Electric Heater Without Delay
-50~20
℃
-10
℃
-50~20
℃
R46
Temp. Diff. between Max. DHW Target Temp. &
Max. Outlet Temp.
0~25
℃
5
℃
0~15
℃
R60
AT to Start Frequency Limit in Cooling
0-60
℃
25
℃
0~60
℃
R61
AT to Stop Frequency Limit in Cooling
0-60
℃
45
℃
0~60
℃
R62
Max. Heat Pump Outlet Water Temp.
40-95
℃
62
℃
40~95
℃
(can not
be 0)
P
Circulating water pump parameters
P01
Operating mode of circulating water
pump(0-Normal/1-Special/2-Intermittent)
0-Normal/1-Special/2-Inter
mittent
2
P02
Circulating water pump operation interval
1~120min
30 Min
Non-zero
P03
Circulating water pump operation duration
1~30min
3 Min
Non-zero
P05
Operating mode of domestic hot water
pump(0-Normal/1-Special/2-Intermittent)
0-Normal/1-Special/2-Inter
mittent
2
P06
Manually controlled water pump
0-
【
No
】
/1-
【
Yes
】
0
P08
【
Water Pump Rating Power
】
0-2000W
0
G
Disinfection parameters
G01
Disinfection Water Temp.
60~70
℃
63
℃
G02
Time Duration of Disinfection
0~60min
0min
G03
Disinfection Starting Time
0~23h
1:00 AM
G04
Interval Period of Disinfection
1~30Days
30
G05
Enable Disinfection
0-
【
No
】
/1-
【
Yes
】
1