52
compressor
selection chart in the
communication
protocol of Rujing
frequency
conversion board
C05
Min. Comp. Frequency in Cooling at Low Ambient
Temp.
0~60Hz
50
C06
Frequency Control Mode
1~120
1
C07
Resonance Point 1
0~120HZ
0
0~120Hz
C08
Resonance Point 2
0~120HZ
0
0~120Hz
C09
Resonance Point 3
0~120HZ
0
0~120Hz
C10
Min. Comp. Frequency in Heating at Low Ambient
Temp.
0~120HZ
60
0-120Hz
C11
Max. Comp. Frequency in Cooling at High Ambient
Temp.
0~120HZ
66
0-120Hz
F
Fan parameters
F01
Fan Motor Type
0-
【
High
】
/1-
【
Double
】
/3-
【
DC
】
3
F02
Coil Temp.. for Max. Fan Speed in Cooling
-15.0~60.0
℃
50
℃
F03
Coil Temp.. for Min. Fan Speed in Cooling
-15.0~60.0
℃
10
℃
F05
Coil Temp.. for Max. Fan Speed in Heating
-15.0~60.0
℃
10
℃
F06
Coil Temp.. for Min. Fan Speed in Heating
-15.0~60.0
℃
20
℃
F10
Fan Quantity
0-
【
One fan
】
/1-
【
Two
fans
】
0
F18
Min. Fan Speed in Cooling
10~1300r
300r
Non-zero
F19
Min. Fan Speed in Heating
10~1300r
300r
Non-zero
F21
Enable Timer Mute
0-
【
No
】
/1-
【
Yes
】
0
F22
Enable Manual-control Fan Speed
0-
【
No
】
/1-
【
Yes
】
0
F23
Rated DC Fan Motor Speed
10~1300r
600r
Non-zero
F25
Max. Fan Speed in Cooling
10~1300r
700r
F26
Max. Fan Speed in Heating
10~1300r
700r
F27
Fan Motor Power Curve
0-100
0
E
Electronic expansion valve parameters
E01
EEV Adjust Mode
0-
【
Manual
】
/1-
【
Auto
】
1