68
Code
2T0032300888
2T0032400274
2T0032800688
2T0032900557
Model
KFU-09HRDN1-QRC8
GW
KFU-12HRDN1-QRC8
GW
KFU-18HRFN1-QRC8
GW
KFU-24HRDN1-QRC8
GW
Compressor
ASN108D22UEZ
ASN108D22UEZ
DA130M1C-31FZ
DA150S1C-20FZ
Indoor fan motor
RPG20E
RPG20E
WZDK30-38G
(
☆
)
RPG45C
Outdoor fan
motor
WZDK36-38G-W
(
★
)
WZDK36-38G-W
(
★
)
WZDK36-38G-W
(
★
)
WZDK50-38G
(
☆
)
Code
2T0032800695
2T0032900561
Model
KFU-18HRFN1-QRD0
GW
KFU-24HRFN1-QRD0
GW
Compressor
DA130M1C-31FZ
DA150S1C-20FZ
Indoor fan motor
WZDK30-38G
(
☆
)
WZDK58-38G
(
☆
)
Outdoor fan
motor
WZDK40-38G-W-1
(
★
)
WZDK50-38G
(
☆
)
Note: The motor marked “
★
”means DC fan motor with control chip in the PCB while the one marked “
☆
” means DC fan
motor with control chip in the fan motor.
2.Compressor checking
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
DA108X1C-23EZ
DA130M1C-31FZ
DA150S1C-20FZ
ASN108D22UEZ
Blue - Red
1.1Ω
(20
℃
)
1.77Ω
(20
℃
)
0.95Ω
(20
℃
)
1.5
Ω
(20
℃
)
Blue -
Black
Red - Blue
Содержание KFU-09HRDN1-QRC8GW
Страница 1: ...12F INVERTER SERIES Service Manual 2013 12FSI A 1310...
Страница 12: ...12 5 Wiring Diagram 5 1 Indoor Unit KFU 09HRDN1 QRC8W KFU 09HRDN1 QRC8GW...
Страница 14: ...14 KFU 24HRDN1 QRC8GW...
Страница 15: ...15 5 2 Outdoor Unit KOB 09HFN1 QRC8W KOB 09HFN1 QRD0GW...
Страница 16: ...16 KOB 12HFN1 QRC8W KOC 18HFN1 QRC4W...
Страница 17: ...17 KOB1 12HFN1 QRD0GW KOZ 18HFN1 QRD0GW KOC1 18HFN1 QRC8GW...
Страница 18: ...18 KOF 24HFN1 QRC8W KOF 24HFN1 QRD0GW KOF 24HFN1 QRC8GW...
Страница 28: ...28 5 Disconnect the charge hose from the vacuum pump...
Страница 30: ...30 Be sure to check for gas leakage...