34
KFU-18HRFN1-QRD0GW, KFU-24HRDN1-QRC8GW , KFU-24HRFN1-QRD0GW models:
Fault temp.
sensor
Operation in cooling,
drying and fan only mode
Operation in heating mode
T1
Run supposed T1=26
℃
high fan speed
Run supposed T1=26
℃
medium fan speed
T2
Normal
During the first 1 minute of compressor operation, indoor
fan shuts off. After that, indoor fan runs at medium fan
speed for 1 minute and then resume to the setting fan
speed.
T3
Run with compressor
frequency
≤
F14
3 minutes’ defrosting every 40 minutes when T4<7
℃
; 2
minutes’ defrosting every 90 minutes when T4≥7
℃
.
T4
Run supposed T4=50
℃
Run supposed T4=15
℃
TP
Run supposed T4=50
℃
Run supposed T4=15
℃
For other models:
Fault temp.
sensor
Operation in cooling, drying
and fan only mode
Operation in heating mode
T1
Run supposed T1=26
℃
high
fan speed
Run supposed T1=26
℃
medium fan speed
T2
Refer to table 1
Refer to table 2
T3
Run with compressor
frequency
≤
F14
3 minutes’ defrosting every 40 minutes when T4<7
℃
;
2 minutes’ defrosting every 90 minutes when T4≥7
℃
.
T4
Run supposed T4=50
℃
Run supposed T4=15
℃
TP
Run supposed T4=50
℃
Run supposed T4=15
℃
T1
25
23
F12
F4(30 minutes on+3
minutes off)
table 1
T1
20
18
F4
F12(Indoor fan 1 minute
off, 1 minute medium fan
speed then the setting
fan speed.)
table 2
8.4.9
Refrigerant leakage detection
This function is only active in cooling mode. It can better prevent the compressor being damaged
by refrigerant leakage or compressor overload.
Open condition:
Define the evaporator coil temp.T2 of the compressor just starts running as Tcool.
In the beginning 5 minutes after the compressor starts up, if T2
<
Tcool
-
2
℃
does not keep continuous 4
Содержание KFU-09HRDN1-QRC8GW
Страница 1: ...12F INVERTER SERIES Service Manual 2013 12FSI A 1310...
Страница 12: ...12 5 Wiring Diagram 5 1 Indoor Unit KFU 09HRDN1 QRC8W KFU 09HRDN1 QRC8GW...
Страница 14: ...14 KFU 24HRDN1 QRC8GW...
Страница 15: ...15 5 2 Outdoor Unit KOB 09HFN1 QRC8W KOB 09HFN1 QRD0GW...
Страница 16: ...16 KOB 12HFN1 QRC8W KOC 18HFN1 QRC4W...
Страница 17: ...17 KOB1 12HFN1 QRD0GW KOZ 18HFN1 QRD0GW KOC1 18HFN1 QRC8GW...
Страница 18: ...18 KOF 24HFN1 QRC8W KOF 24HFN1 QRD0GW KOF 24HFN1 QRC8GW...
Страница 28: ...28 5 Disconnect the charge hose from the vacuum pump...