Initial Start
7 --- 22
If the insertion key (3) at the door interlock is incorrectly aligned, inad-
vertent shutdown of the compressor package can occur.
The insertion key (3) align with the door interlock switch (1) without
binding against the sides of the interlock switch when the maintenance
door is closed.
If necessary, re---align the insertion key (3).
Loosen the bolts (4).
Align the insertion dey (3) so that it glides smoothly into the interlock switch (1).
If necessary, use washers to help align the insertion key (3) with the interlock
switch (1).
Tighten the bolts (4) again.
1
4
4
3
2
2
6
5
1 Door interlock switch
4
Bolt
2 Clamping nut
5
Frame
3 Insertion key
6
Maintenance door
Functional check of the interlock switch
A functional check of the door interlock switch must be made after in-
itial start.
Start the compressor package (see chapter 8.3).
Open the left ---hand maintenance door --- the compressor package will shut down im-
mediately if the door interlock switch functions correctly.
Close the left ---hand maintenance door.
Reset the alarm message by pressing the acknowledge (reset) key (11, see
chapter 8.2.1) on SIGMA CONTROL.
The compressor package is now ready to start again.
Attention!
Attention!
Содержание SM 8
Страница 9: ...Technical Specification 1 6...
Страница 16: ...Construction and Operation 5 13...
Страница 17: ...Construction and Operation 5 14...
Страница 54: ...Appendix 11 51 11 Appendix 11 1 Wiring Diagram...
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 74: ...SM 8 SM 11 A 08 B 07 C 14 D 11...
Страница 76: ......
Страница 78: ......
Страница 80: ......
Страница 82: ......