Kaden Installer's Manual
Ducted Gas Heaters
Kaden heaters are designed to provide a central source of heat for a ducted central heating system.
Kaden heaters should not be installed downstream from an air washer, an evaporative cooler or refrigerative
cooling system. Nor are they designed to be installed on a marine craft, houseboat, or any similar environment.
Kaden heaters must be installed in accordance with these instructions and related regulations, codes, standards,
and authorities. These include but may not be limited to:
•
Kaden Sizing Guide
•
AS/NZS 5601 - Gas installations
•
AS 4254 - Ductwork for air-handling systems in buildings
•
Local Building Regulations
•
HB 276 - A Guide to Good Practice
•
Environment Authorities
•
Local Gas and Electricity Authority Codes
•
Building Code of Australia (BCA)
IMPORTANT
The installer assumes the responsibility for equipment installed in violation of any code, regulations
and these installation instructions.
It is recommended the Kaden Sizing Guide be followed in estimating heating requirements and
for system design that will result in efficient installation and provide a higher level of comfort and
economical operation.
For the hourly input and the gas type to be used, see the appliance data label located inside the
service compartment or the "11. Technical Specifications" on page 36.
1.1 INSPECTION
This appliance has been inspected and tested at the time of manufacture, packaged and released for transportation
without known damage. Upon receipt, inspect the exterior for evidence of rough handling in shipment.
Ensure that the appliance is labelled correctly for the gas to which it is intended to be connected. Immediately
report to supplier any discrepancies or damage.
1.2 UNPACKING THE HEATER
Heaters are supplied with a box cover. To unpack:
•
Cut and remove any nylon straps.
•
Lift the box off and dispose of thoughtfully.
•
Remove the packaging and dispose of thoughtfully.
NOTE
Always remove and dispose of the plastic film before mounting the heater onto a base box (if
fitted).
1.3 UNLOADING OR LIFTING THE HEATER
When unloading or lifting the heater, ensure lifting equipment is in good operating condition and capable of lifting
the total load.
Ensure there is a clear area to place the heater down, which is within reach of the lifting equipment.
NOTE
If fitting the heater to elevated heights such as a roof, use suitable lifting equipment.
1. GENERAL GUIDELINES