24
Kaden Installer's Manual
Ducted Gas Heaters
5. FAN SPEED KUN3, KEX3 & KEX4
5.1 FAN SPEED SETTING FOR KUN3, KEX3 & KEX4 MODELS
There are three fixed fan speed options available on KUN3, KEX3 and KEX4 models, these are:
•
High
- “HIGH” (Factory Default)
•
Medium
- “MED”
•
Low
- “LOW”
5.1.1 To Adjust The Fan Speed
Ensure the power supply to the unit is OFF at the fixed switched socket outlet adjacent to the heater
Access the controls and change as required:
COMMON
LOW
MED
HIGH
SPEED
Fan speed high
(Factory Default Connections)
Fan speed medium
LOW
MED
HIGH
COMMON
SPEED
Fan speed low
LOW
MED
HIGH
COMMON
SPEED
Diagram 17
•
For High fan speed do not adjust
•
For Medium fan speed move terminal from “HIGH” to “MED”
•
For Low fan speed move terminal from “HIGH” to “LOW”
•
Turn the power back on once complete
IMPORTANT
When setting the fan speed
ONLY
move the HIGH, MED and LOW connection,
DO NOT
alter the
common connection.