KACO blueplanet 3.0 NX3 M2 KACO blueplanet 5.0 NX3 M2 KACO blueplanet 8.0 NX3 M2 KACO blueplanet 10.0 NX3 M2
KACO blueplanet 15.0 NX3 M2 KACO blueplanet 20.0 NX3 M2
Page 38
9.8.5
View available inverters
All inverters are connected via a
communication unit.
1.
Press the <inverter search> button.
Note
: Up to 5 inverters can be connected
to one communication unit. When the
button is pressed, the communication unit
scans the connected inverters and
automatically assigns the RS485 address
and saves it in the communication unit.
2.
The desired inverter can now be
selected for further parameter
settings under <Available inverters>.
3.
Adjust the parameters in <Parameter
settings>.
>> see Chapter 9.11.6 on page 36 or:
View feed-in values of the selected
device in <Live values> >> see Chapter
»
Device configured with country setting.
Fig. 75.
Select inverter
Fig. 76.
Select the required inverter
9.9
Menu of Inverter
9.9.1
Viewing the instantaneous values
The required device is selected in
<Available inverters> and the <Inverter
values & settings> menu is opened.
1. Select <Live values> and view
information about the installation.
Note:
All measured values for your PV
system and the grid power are
displayed. In addition, after solar feed-
in, the daily values and yields are
displayed.
Note:
The measured values are only
displayed for the selected device. A
simultaneous evaluation of all inverters
can only be carried out via our
“blueplanet web” monitoring portal.
2. View current Power and Power Factor.
3. View pending errors via <Error Code>.
N/A = no error
Note:
In the event of a pending error,
note the
Error code list
in chapter 10.5
on page 59.
Fig. 77.
Viewing the live values
Fig. 78.