25
I
NTERFACE
H
ARDWARE
, C
OVERS
Cable Assemblies
These steps involve attaching the two stainless steel mechanical cable assemblies to the lock and Rim Exit
Device chassis, respectively; connecting these cable assemblies; and adjusting the cable length to achieve
proper timing of the high security lock bolt retraction relative to the Rim Exit Device latchbolt.
Install Lock Cable Assembly
1.
Locate the correct lock cable assembly
needed for the handing of your installa-
tion. The bag labeled with part number
114048 contains the LHR lock cable as-
sembly. The bag labeled with part num-
ber 114047 contains the RHR lock cable
assembly. The lock cable assembly has
a brass ball-end plug on one end and a
turnbuckle secured by a brass ball-end
plug on the other end.
Note:
The LHR lock cable assembly is
approximately 1/4 inch shorter than the
RHR lock cable assembly.
2.
Detach the lock pulley cover from the pul-
ley assembly by removing the #6-32 x
1/4” flat head screw.
3.
Refer to Figure 18 or Figure 19 depend-
ing on the handing of your installation.
Insert the brass ball-end plug of the lock
cable assembly into the face of the lock
pulley and thread the cable counterclock-
wise around the pulley. Position the lock
pulley cover over the locating pin on the
pulley and secure the cover to the pulley
with the #6-32 x 1/4” flat head screw.
Figure 18 - Lock Cable Assembly - RHR
Figure 19 - Lock Cable Assembly - LHR