For Professional Technical Support call 1-844-242-2475 9
4. WELL TO PUMP CONNECTION
Shallow Well Application Only
1.
Thread
1-1/4in. PVC MPT×S Male Adapter
into
pump. Cement a short horizontal
1-1/4 in.
PVC rigid
Pipe
into adapter. (Fig .1)
2.
Cement a
1-1/4in. PVC Slip× Slip Union
into a short
horizontal 1-1/4 in.PVC rigid Pipe.
Slopes all inlet
piping slightly upward from well to the pump to
prevent trapping air
.(Fig.2)
3. Completed installation is shown Fig. 3a.3b.3c.
For Cased well
For Well Point
For Surface water
Deep Well Application Only
1.
Remove two bolts, take the shallow well ejectors
included venture and nozzle out, take out gasket seal.
(Fig. 1)
2.
Install
1-1/4in. PVC MPT×S Male Adapter at the top
tapping
and
1in. ×3in.Galv.Steel Nipple
at the
bottom tapping of pump face. Thread
1in. PVC FPT×S
Female Adapter
into
the nipple. Cut 1in. pipe and
1-1/4in. pipe. Cement them to the adapter and tee
assembling in the previous step
INSTALLING
PIPING IN WELL
.
(Fig. 2)
3. Completed installation is shown. (Fig. 3)
Note: slopes all inlet piping slightly upward from well to the pump to prevent trapping air.