background image

For Professional Technical Support call 1-844-242-2475                                                                                                                    3 

 

4. 

DANGER

Risk of hazardous pressure. Stand clear of pump and filter during start-up. Pool and spa circulation 

systems operate under high pressure. When any part of the circulating system (i.e. locking ring, pump, filter, 
valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the pump 
housing cover filter lid and valves to violently separate which can result in severe personal injury or death. Filter 
tank lid and strainer cover must be properly secured to prevent violent separation. Stand clear of all circulation 
system equipment when turning on or starting up pump. Before servicing pool and spa equipment, make note of 
the filter pressure. Be sure that all controls are set to ensure the system cannot inadvertently start during service. 
Turn off all power to the pump. Place filter manual air relief valve in the open position and wait for all pressure in 
the system to be relieved. Before starting the system, fully open the manual air relief valve and place all system 
valves in the “open” position to allow water to flow freely from the pool and spa back to the pool or spa. Stand 
clear of all pool and spa equipment and start the pump. Do not close filter manual air relief valve until all pressure 
has been discharged from the valve and a steady stream of water appears. Observe filter pressure gauge and be 
sure it is not higher than the pre-service condition. 

5. 

DANGER

: ALWAYS disconnect the power to the pump before servicing. 

6. 

WARNING

: Risk of harm. A clearly labeled emergency shut-off switch for the pool pump and spa jet pump must 

be in an easily accessible, obvious place near the pool or spa. Make sure bathers know where it is and how to 
use it in case of emergency. 

7. 

WARNING

Risk of harm. To reduce the risk of injury, do not permit children to use this product unless they are 

closely supervised at all times. 

8. 

WARNING

Risk of hazardous pressure. Pool and spa circulation systems operate under high pressure. 

Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Read and follow 
instructions in owner’s manual when installing and operating equipment. Have a trained pool professional perform 
all pressure tests. Do not connect system to a high pressure or city water system. Use equipment only in a pool 
or spa installation. Trapped air in the system can cause explosion. BE SURE all air is out of the system before 
operating or testing the equipment. See the hazardous pressure warning below. Do not use compressed air to 
clean, test, or purge equipment for winter. 

9. 

WARNING

All work must be performed by a qualified pool professional, and must conform to all national, state, 

and local codes. 

10. 

WARNING

Risk of harm. Pumps improperly sized or installed or used in applications other than for which the 

pump was intended can result in severe personal injury or death. These risks may include but not be limited to 
electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by a structural 
failure of the pump or other system component. 

11. 

CAUTION

Install to provide drainage of compartment for electrical components. 

12. 

CAUTION

These instructions contain information for a variety of pump models and therefore some instructions 

may not apply to a specific model. All models are intended for use in swimming pool applications. The pump will 
function correctly only if it is properly sized to the specific application and properly installed. 

13. 

CAUTION

Electrical controls such as on/off switches, timers, and control systems, etc. should be properly 

installed to allow the operation (start-up, shut-down, or servicing) of any pump or filter without requiring the user 
to place any portion of his/her body over or near the pump strainer lid or filter lid. Such installation should allow 
the user to stand clear of the filter and pump during system start-up, shut down or servicing of the system. Never 
open the inside of the drive motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when 
there is no power to the unit. The pump is not submersible. The pump is designed for use with chlorinated pools 
only. For use with other applications, contact customer service. The pump is capable of high flow rates; use 

Содержание PPI10001SPK

Страница 1: ...R S MANUAL 2 SPEED POOL PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2020 GP Enterprises Co Ltd K2Man 31 Rev 12 28 20 ...

Страница 2: ...of the body is held against the drain cover trapping the swimmer underwater This hazard is present when the drain cover is missing or broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage ...

Страница 3: ...ested equipment may fail causing severe injury or property damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests Do not connect system to a high pressure or city water system Use equipment only in a pool or spa installation Trapped air in the system can cause explosion BE SURE all air is out of the ...

Страница 4: ... cover is properly installed Replace drain covers as necessary Drain covers deteriorate over time due to exposure to sunlight pool chemicals and weather Avoid getting hair limbs or body in close proximity to any suction cover pool drain or outlet Disable suction outlets or reconfigure into return inlets 16 IMPORTANT Before pressure testing make the following safety checks Check all clamps bolts li...

Страница 5: ... 1 2 in Slip Half Union Kit included with the pump Only qualified licensed personnel should install pump and wiring Pump mount must Be located away from corrosive or flammable liquids Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating Max Amb listed on the motor model plate If this pump is installed in an enclosure pump house the enclosure must ...

Страница 6: ...ICE Support all piping connected to pump Piping Use at least 1 1 2 in 38 mm pipe Use 2 in 51 mm pipe if possible Increase size if a long run is needed To avoid strains on the pump support both suction and discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid air l...

Страница 7: ...on outlet is completely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification Suction outlet covers must have been tested by recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction ...

Страница 8: ...ire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 ft 1 5 m of the inside walls of swimming pool spa or hot tub To Wire a Two Speed Motor NOTIC...

Страница 9: ...otor to prevent dirt bugs etc from entering Table l Recommended Fusing Data Motor HP Branch Fuse Rating Amps Max Load Amps Voltage Hz Phase Service to Motor Distance in Ft m 0 300 0 90 AWG Wire Size mm2 1 15 5 1 230 60 1 14 2 1 1 2 15 6 6 230 60 1 Time delay fuses are recommended instead of standard fuses in any motor circuit OPERATION STORAGE WARNING Risk of explosion Before removing trap cover N...

Страница 10: ...pa system Propylene glycol or RV antifreeze is non toxic and will not damage plastic system components other anti freeze formulas are highly toxic and may damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see Draining Pump Keep motor dry and covered during storage To avoid condensation corrosion pr...

Страница 11: ...egular maintenance is needed beyond reasonable care and periodic cleaning of the strainer basket If shaft seal is worn or damaged repair as follows Pump Disassembly Removing Old Seal Before disassembly disconnect power to pump motor Be sure gate valves on suction and return piping are closed Release all pressure by opening all vents 1 Drain pump by removing drain plugs on bottom of pump body and t...

Страница 12: ...k 4 Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 6 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 7 Slide rotating seal member polished carbon face out over impeller sleeve until rubber...

Страница 13: ... is not clogged if it is clean trap and strainer Make sure impeller is not clogged follow instructions in Removing Old Seal check impeller for clogging follow instructions in Installing New Seal for reassembly Impeller and diffuser may be worn If so order replacement parts by calling customer service Problem Possible Cause Corrective Action The pump may be running too slow There is an error in the...

Отзывы: