4                                                                                                                    For Professional Technical Support call 1-844-242-2475 

 

caution when installing and programming to limit the pump's performance potential with old or questionable 
equipment. This appliance is not intended for use by persons (including children) of reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning the use of the appliance by a person responsible for their safety. 

14. 

CAUTION

: Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, 

all Occupational Safety and Health Administration (OSHA) guidelines must be followed. 

15. 

IMPORTANT

To minimize the risk of injury due to suction entrapment hazard: Pools and spas should utilize a 

minimum of two drains per pump. A properly installed and secured ANSI/ASMEA112.19.8 approved anti-
entrapment suction cover must be used for each drain. Each suction cover must be installed at least three (3’) 
feet apart, as measured from the nearest point to nearest point. Regularly inspect all covers for cracks, damage 
and advanced weathering. If a cover becomes loose, cracked, damaged, or broken, or is missing, close the pool 
or spa immediately, shut off the pump, post a notice and keep the pool or spa closed until an appropriate certified 
cover is properly installed. Replace drain covers as necessary. Drain covers deteriorate over time due to 
exposure to sunlight, pool chemicals and weather. Avoid getting hair, limbs or body in close proximity to any 
suction cover, pool drain or outlet. Disable suction outlets or reconfigure into return inlets. 

16. 

IMPORTANT

Before pressure testing, make the following safety checks: Check all clamps, bolts, lids, and 

system accessories before testing. Release all air in system before testing. Tighten pump trap lids to 30 ft. lbs. 
(4.1 kg-m) torque for testing. Water pressure for test must be less than 25 PSI (7.5 kg/cm2). Water temperature 
for test must be less than 100° F (38 °C). Limit test to 24 hours. After a test, visually check the system to ensure 
that it is ready for operation. Remove the trap lid and re-tighten it by hand only. 

NOTICE

: These testing parameters apply only to the models described herein. For other equipment, consult the 

manufacturer. 

PRE-INSTALLATION 

 

APPLICATION 

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do 
not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it 
cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for 
storage and reassembled to its original integrity. 

TOOLS REQUIRED 

 
 
 

 
 
 
 
 

 

 

 

 

Phillips 

Screwdrive

 

Flathead 

Screwdrive

 

 

Wrenc

Safety  

Goggles

 

Pipe Wrench 

Hacksaw 

Tape 
Measure 

Thread Tape 

PVC Glue 

Содержание PPI10001SPK

Страница 1: ...R S MANUAL 2 SPEED POOL PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2020 GP Enterprises Co Ltd K2Man 31 Rev 12 28 20 ...

Страница 2: ...of the body is held against the drain cover trapping the swimmer underwater This hazard is present when the drain cover is missing or broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage ...

Страница 3: ...ested equipment may fail causing severe injury or property damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests Do not connect system to a high pressure or city water system Use equipment only in a pool or spa installation Trapped air in the system can cause explosion BE SURE all air is out of the ...

Страница 4: ... cover is properly installed Replace drain covers as necessary Drain covers deteriorate over time due to exposure to sunlight pool chemicals and weather Avoid getting hair limbs or body in close proximity to any suction cover pool drain or outlet Disable suction outlets or reconfigure into return inlets 16 IMPORTANT Before pressure testing make the following safety checks Check all clamps bolts li...

Страница 5: ... 1 2 in Slip Half Union Kit included with the pump Only qualified licensed personnel should install pump and wiring Pump mount must Be located away from corrosive or flammable liquids Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating Max Amb listed on the motor model plate If this pump is installed in an enclosure pump house the enclosure must ...

Страница 6: ...ICE Support all piping connected to pump Piping Use at least 1 1 2 in 38 mm pipe Use 2 in 51 mm pipe if possible Increase size if a long run is needed To avoid strains on the pump support both suction and discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid air l...

Страница 7: ...on outlet is completely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification Suction outlet covers must have been tested by recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction ...

Страница 8: ...ire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 ft 1 5 m of the inside walls of swimming pool spa or hot tub To Wire a Two Speed Motor NOTIC...

Страница 9: ...otor to prevent dirt bugs etc from entering Table l Recommended Fusing Data Motor HP Branch Fuse Rating Amps Max Load Amps Voltage Hz Phase Service to Motor Distance in Ft m 0 300 0 90 AWG Wire Size mm2 1 15 5 1 230 60 1 14 2 1 1 2 15 6 6 230 60 1 Time delay fuses are recommended instead of standard fuses in any motor circuit OPERATION STORAGE WARNING Risk of explosion Before removing trap cover N...

Страница 10: ...pa system Propylene glycol or RV antifreeze is non toxic and will not damage plastic system components other anti freeze formulas are highly toxic and may damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see Draining Pump Keep motor dry and covered during storage To avoid condensation corrosion pr...

Страница 11: ...egular maintenance is needed beyond reasonable care and periodic cleaning of the strainer basket If shaft seal is worn or damaged repair as follows Pump Disassembly Removing Old Seal Before disassembly disconnect power to pump motor Be sure gate valves on suction and return piping are closed Release all pressure by opening all vents 1 Drain pump by removing drain plugs on bottom of pump body and t...

Страница 12: ...k 4 Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 6 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 7 Slide rotating seal member polished carbon face out over impeller sleeve until rubber...

Страница 13: ... is not clogged if it is clean trap and strainer Make sure impeller is not clogged follow instructions in Removing Old Seal check impeller for clogging follow instructions in Installing New Seal for reassembly Impeller and diffuser may be worn If so order replacement parts by calling customer service Problem Possible Cause Corrective Action The pump may be running too slow There is an error in the...