PERFORMANCE 

 

Model 

HP 

GPM of Water @ Total Feet of Lift (high speed) 

Max. 

Lift 

0 ft. 

10 ft. 

20 ft. 

30 ft. 

40 ft. 

50 ft. 

PPI10001SPK 

75.0 

68.0 

56.0 

43.3 

25.0 

48 ft. 

PPI15001SPK 

1-1/2 

96.0 

86.0 

76.0 

64.0 

50.0 

32.0 

65 ft. 

 

Model 

HP 

GPM of Water @ Total Feet of Lift (low speed) 

Max. 

Lift 

0 ft. 

10 ft. 

20 ft. 

30 ft. 

40 ft. 

50 ft. 

PPI10001SPK 

37.0 

15.0 

13 ft. 

PPI15001SPK 

1-1/2 

48.0 

27.0 

17 ft. 

 

SAFETY INSTRUCTIONS 

 

1. 

DANGER

Risk of suction entrapment. Always turn off all power to the pool pump before installing the cover or 

working on any suction outlet. This pump produces high levels of suction and creates a strong vacuum at the 
main drain at the bottom of your pool or spa. This suction is so strong that it can trap adults or children under 
water if they come in close proximity to a pool or spa drain or a loose or broken drain cover or grate. Stay off the 
main drain and away from all suction outlets! 

2. 

DANGER

Risk of suction entrapment. The use of unapproved covers or allowing use of the pool or spa when 

covers are missing, cracked or broken can result in body or limb entrapment, hair entanglement, body 
entrapment, evisceration and/or death. Limb Entrapment: When a limb is sucked or inserted into an opening 
resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, 
cracked or not properly secured. Hair Entanglement: When the hair tangles or knots in the drain cover, trapping 
the swimmer underwater. This hazard is present when the flow rating of the cover is too small for the pump or 
pumps. Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer 
underwater. This hazard is present when the drain cover is missing or broken, or the cover flow rating is not high 
enough for the pump or pumps. Evisceration/Disembowelment: When a person sits on an open pool (particularly 
a child wading pool) or spa outlet and suction is applied directly to the intestines, causing severe intestinal 
damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly secured. 
Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening 
of an outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not 
properly secured. 

NOTICE

: All suction plumbing must be installed in accordance with the latest national and local codes for 

swimming pools, spas and hot tubs, including NSPI standards and CPSC guidelines. 

3. 

DANGER

Risk of electric shock. Can shock, burn or kill. Connect only to a branch circuit protected by a ground-

fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a 
GFCI. This unit must be connected only to a supply circuit that is protected by a ground fault circuit-interrupter 
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the 
GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If 
the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without 
the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use 
this pump. Disconnect the pump and have the problem corrected by a qualified service representative before 
using. 

Содержание PPI10001SPK

Страница 1: ...R S MANUAL 2 SPEED POOL PUMP Questions problems missing parts Before returning to the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 www K2pumps com Copyright 2020 GP Enterprises Co Ltd K2Man 31 Rev 12 28 20 ...

Страница 2: ...of the body is held against the drain cover trapping the swimmer underwater This hazard is present when the drain cover is missing or broken or the cover flow rating is not high enough for the pump or pumps Evisceration Disembowelment When a person sits on an open pool particularly a child wading pool or spa outlet and suction is applied directly to the intestines causing severe intestinal damage ...

Страница 3: ...ested equipment may fail causing severe injury or property damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests Do not connect system to a high pressure or city water system Use equipment only in a pool or spa installation Trapped air in the system can cause explosion BE SURE all air is out of the ...

Страница 4: ... cover is properly installed Replace drain covers as necessary Drain covers deteriorate over time due to exposure to sunlight pool chemicals and weather Avoid getting hair limbs or body in close proximity to any suction cover pool drain or outlet Disable suction outlets or reconfigure into return inlets 16 IMPORTANT Before pressure testing make the following safety checks Check all clamps bolts li...

Страница 5: ... 1 2 in Slip Half Union Kit included with the pump Only qualified licensed personnel should install pump and wiring Pump mount must Be located away from corrosive or flammable liquids Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating Max Amb listed on the motor model plate If this pump is installed in an enclosure pump house the enclosure must ...

Страница 6: ...ICE Support all piping connected to pump Piping Use at least 1 1 2 in 38 mm pipe Use 2 in 51 mm pipe if possible Increase size if a long run is needed To avoid strains on the pump support both suction and discharge pipes independently Place these supports near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump To avoid air l...

Страница 7: ...on outlet is completely blocked The flow through the remaining main drain s must comply with the latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications Testing and Certification Suction outlet covers must have been tested by recognized testing laboratory and found to comply with the latest ASME ANSI Specifications for Suction ...

Страница 8: ...ire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub and to all electrical equipment metal piping or conduit within 5 ft 1 5 m of the inside walls of swimming pool spa or hot tub To Wire a Two Speed Motor NOTIC...

Страница 9: ...otor to prevent dirt bugs etc from entering Table l Recommended Fusing Data Motor HP Branch Fuse Rating Amps Max Load Amps Voltage Hz Phase Service to Motor Distance in Ft m 0 300 0 90 AWG Wire Size mm2 1 15 5 1 230 60 1 14 2 1 1 2 15 6 6 230 60 1 Time delay fuses are recommended instead of standard fuses in any motor circuit OPERATION STORAGE WARNING Risk of explosion Before removing trap cover N...

Страница 10: ...pa system Propylene glycol or RV antifreeze is non toxic and will not damage plastic system components other anti freeze formulas are highly toxic and may damage plastic components in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see Draining Pump Keep motor dry and covered during storage To avoid condensation corrosion pr...

Страница 11: ...egular maintenance is needed beyond reasonable care and periodic cleaning of the strainer basket If shaft seal is worn or damaged repair as follows Pump Disassembly Removing Old Seal Before disassembly disconnect power to pump motor Be sure gate valves on suction and return piping are closed Release all pressure by opening all vents 1 Drain pump by removing drain plugs on bottom of pump body and t...

Страница 12: ...k 4 Replace slinger on end of motor shaft so that impeller sleeve will push it into position If slinger shows signs of wear or damage replace it 5 Remount seal plate on motor Tighten bolts to 60 80 inch lbs 69 92 kg cm torque 6 Apply a small amount of liquid detergent to inside diameter of rotating half of seal 7 Slide rotating seal member polished carbon face out over impeller sleeve until rubber...

Страница 13: ... is not clogged if it is clean trap and strainer Make sure impeller is not clogged follow instructions in Removing Old Seal check impeller for clogging follow instructions in Installing New Seal for reassembly Impeller and diffuser may be worn If so order replacement parts by calling customer service Problem Possible Cause Corrective Action The pump may be running too slow There is an error in the...

Отзывы: