KTI-81798S 3  12/11/17

Drain Daily

Regulator

Oiler

Quick Coupler

Leader

Hose

 

Nipple

 Do Not Install

Quick Coupling

Here

 

 

Nipple

 

Filter

 

Air Supply

 

Whip Hose

AIR SUPPLY

Tools operate on a wide range of air pressures.  It is recommended that air pressure measures 90 psig at the tool with the trigger fully depressed and 

no load applied to the tool.  Higher pressure (over 90 psig; 6.2 bar) raises performance beyond the rated capacity of the tool, which will shorten tool 

life and could cause injury.
Always use clean, dry air. Dust, corrosive fumes, and/or water in the air line will cause damage to the tool. Drain water from air lines and compressor 

prior to running tool. Clean the air inlet filter screen weekly. The recommended hookup procedure can be viewed in the below figure. 
The air inlet used for con nect ing air supply, has stan dard 1/2" NPT American Thread. Line pressure should be increased to compensate for unusually 

long air hoses (over 25 feet). Minimum hose diameter should be 1/2" I.D. Fittings should have the same inside dimensions and should be tightly secured. 
Ensure an accessible emergency shut off valve has been installed in the air supply line and make others aware of its location.

LUBRICATION

Lubricate the air motor daily with high quality air tool oil. If no air line oiler is used, run 1/2 oz. of oil through the tool. The oil can be squirted into the 

tool air inlet or into the hose at the nearest connection to the air supply, then run the tool. A rust inhibitive oil is acceptable for air tools.  

 

       After an air tool has been lubricated, oil will discharge through the exhaust port during the first few seconds of operation.  The exhaust port must 

be covered with a towel before applying air pressure to prevent serious injury.

TROUBLESHOOTING

Other factors outside the tool may cause loss of power or erratic action. Reduced compressor output, excessive drain on the air line, moisture or 

restrictions in air pipes or the use of hose connections of improper size or poor conditions may reduce air supply. Grit or gum deposits in the tool 

may cut power and may be corrected by cleaning the air strainer and flushing out the tool with gum solvent oil or an equal mixture of SAE #10 and 

kerosene. If outside conditions are in order, disconnect tool from hose and take tool to your nearest authorized service center.

OPERATION

This tool is an impacting tool and not a torque meter. When specific torque is required, it must be checked with a torque meter after fitting the fastener 

with the Impact.
If a fastener does not move within five seconds, use a larger size Impact. Do not use Impact Wrench beyond rated capacity, as this can drastically 

reduce the tool life.

NOTE:  During operation, safety goggles must always be worn to guard against flying debris (users & bystanders).
Always turn off the air supply, drain hose of air pressure and detach tool from air supply before installing, removing or adjusting any part or 

accessory on this tool, or before performing any maintenance on this tool.
NOTE:

 

Actual torque on a fastener is directly related to joint hardness, tool speed, con di tion of socket and the time the tool is al lowed to impact.

Use the simplest possible tool-to-socket hook up. Every con nec tion absorbs energy and reduces power.

WARNING

Содержание KTI-81798S

Страница 1: ...cts or other reproductive harm Some examples of these chemicals are lead from lead based paints crystalline silica from bricks cement and other masonry products and arsenic and chromium from chemicall...

Страница 2: ...efore installing removing or adjusting any accessory on this tool or before performing any maintenance on this tool Failure to do so could result in injury Whip hoses can cause serious injury Always c...

Страница 3: ...tool has been lubricated oil will discharge through the exhaust port during the first few seconds of operation The exhaust port must be covered with a towel before applying air pressure to prevent ser...

Страница 4: ...KTI 81798S 4 12 11 17 5 SPLINE DRIVE IMPACT WRENCH WITH 6 EXTENDED ANVIL OWNERS MANUAL KTI 81798S...

Страница 5: ...98A25 Rotor Blade pack of 5 1 26 Spring type Straight Pin Incl w 20 2 27 Cylinder Incl w 20 1 REF NO PART NO DESCRIPTION QTY 28 KTP81798A28 Spring type Straight Pin 1 29 KTP81798A29 Rear Plate 1 30 KT...

Страница 6: ...thorized warranty service centers The foregoing obligation is K Tool International sole liability under this or any implied warranty and under no circumstances shall we be liable for any incidental or...

Страница 7: ...je en espacios bien ventilados y trabaje con equipos de seguridad aprobados tales como las mascarillas contra el polvo dise adas espec ficamente para detener part culas microsc picas ADVERTENCIA ADVER...

Страница 8: ...ier pieza o accesorio de esta herramienta o antes de realizar cualquier mantenimiento de ella Caso omiso en hacerlo podr a ocasionar alguna lesi n Las mangueras de l tigo pueden ocasionar heridas seri...

Страница 9: ...ocasionar la disminuci n de potencia de la herramienta LOCALIZATI N Y CORRECCI N DE FALLAS Puede haber otros factores ajenos a la herramienta que sean causa de p rdida de corriente o acci n err tica...

Страница 10: ...a bajo la responsabilidad exclusiva de K Tool International seg n se menciona o de cualquier garant a impl cita y bajo ninguna circunstancia quedar bajo su responsabilidad cualquier garant a impl cita...

Страница 11: ...utilisation de certains mat riaux Pour r duire l exposition il est recommand de travailler dans un endroit bien a r et de porter de l quipement de protection approuv tel qu un masque antipoussi re sp...

Страница 12: ...pourrait causer des blessures Les tuyaux souples peuvent causer de graves blessures V rifiez toujours le boyaux et les raccords et remplacez les s ils sont endommag s fissur s ou l ches vitez d utilis...

Страница 13: ...ou dans le tuyau au raccordement le plus pr s puis faites fonctionner l outil N utilisez pas plus de 1 2 onces d huile car un remplissage excessif causera une r duction de la puissance de l outil D P...

Страница 14: ...L obligation qui pr c de constitue la seule responsabilit de K Tool International en vertu de cette garantie ou de toute garantie implicite et en aucun cas K Tool International ne pourra tre responsab...

Отзывы: