![K-TEK RS80 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/k-tek/rs80/rs80_installation-and-operators-manual_648646007.webp)
RS80-0200-1 Rev d (10-2010)
DCN0533
7
2.1.7 Mounting for Low Viscosity Liquids
Mounting positions for low viscosity liquids are shown below. If the Resonator fork is nozzle mounted with a flange
and does not extend beyond the wall of the vessel, a minimum nozzle diameter of 2” is required. If mounted into a
threaded nozzle, forks should
protrude past the wall of the ves-
sel.
* Deburr the nozzle surfaces
2.1.6 Mounting for High Viscosity Liquids
High viscosity liquids require proper mounting to ensure accurate, repeatable service. With high viscosities, the opti-
mum mounting is vertical from the vessel top or horizontal (flush mounted from the side).
Note:
Horizontal mounting: Position the forks so that the narrow edge of the tines are vertical. This ensures that
the liquid or gelatinous process can run off easily.
Vertical Top Mounted
Flush Side Mounted
2.1.8 Pipe Mounting and Empty Pipe Detection
The Resonator can be mounted into pipe lines of 2” and larger diameters. Installation into a 1” pipe line is possible
using a 1” tee (1 x 3/4” reducer fitting).
Note: To avoid blockage of the flowing material, ensure narrow edge of forks is parallel with pipe walls.
To maintain optimum performance in flow or no flow applica-
tions, the liquids should have low viscosities and low flow veloci-
ties.
Empty Pipe Detection
*
Содержание RS80
Страница 1: ...RS80 RS85 ...