![K-TEK RS80 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/k-tek/rs80/rs80_installation-and-operators-manual_648646016.webp)
RS80-0200-1 Rev d (10-2010)
DCN0533
5.2 Time Delay (RS85 only)
The RS85 Time Delay option allows changing the time response of the output relay, which is very useful in applica-
tions with severe turbulence or agitation.
In typical applications, the RS85 with its default settings will activate the relays instantaneously when the switch
point has been reached. In certain applications it may be necessary to delay the action of the relays in the switch. If
this is desired, a Time Delay for the relays can be set. To enter the Time Delay Setup Mode, place the magnet on
“S1” for more than 1 second but less than 6 seconds. The following sequence of LED’s will be observed:
While LED2 is lit
RED
, LED1 will blink the current Time Delay setting per Table 6.
After LED2 turns “off”, LED1 will blink in correspondence to the different Time Delay settings per Table 4. When the
desired Time Delay is reached, place the magnet on the “S1” position (See Figure 17). The Time Delay will be set
and the RS85 will return to normal operation. If a time delay is not selected, the RS85 will return to its current operat-
ing mode without changing the current Time Delay setting. During normal operation of the switch, if a Time Delay is
selected other than 0 seconds, LED1 will change color when the switch point has been reached (See Figure 18).
The relays will respond after the elapsed Time Delay on both energized and de-energized actions.
Table 7 - Time Delay Adjustment
OPERATION
LED 1
LED 2
Normal
GREEN OR RED
OFF
S1 for 1 - 6 Seconds
OFF
OFF
Displaying Current Time Delay
“GREEN”
RED
OFF
OFF
S1 PER Table 6
“GREEN”
OFF
“_” - indicates a blinking LED
Table 8 - Time Delay Setting
LED1 Blinks 1
2
3
4
5
6
7
8
Seconds
0
5
10
15
20
25
30
35
Figure 17
Figure 18
Содержание RS80
Страница 1: ...RS80 RS85 ...
Страница 24: ...RS80 0200 1 Rev d 10 2010 DCN0533 ...