background image

RPS GEAR DRIVEN SPRINKLER SETTING INSTRUCTIONS

CHANGING A NOZZLE

1

REMOVING THE NOZZLE RETENTION SCREW

Use the hex key end “A” of the universal tool to remove
the nozzle retention screw by turning counter-clockwise
to remove and clockwise to re-install.

2

PULL UP THE RISER

Insert the “B” end of the universal tool in the keyhole on the
top of the nozzle turret and turn the key 1/4 turn to insure
that the key does not slip out of the keyhole when you pull
it up. Firmly pull up the entire spring-loaded riser to access
the nozzle socket. Hold the riser assembly with one hand.

3

REMOVING THE  NOZZLE

With the nozzle retention screw removed, the nozzle may
be removed by either turning on the water (wear safety
glasses when using this method), or by pulling outward
on the nozzle prongs with a pair of needle-nose pliers.

4

INSTALLING A NOZZLE

Press the desired nozzle into the nozzle socket. Make
sure the nozzle number is visible and the nozzle “prongs”
are up. Then, re-install the nozzle retention screw.
NOTE: The nozzle retention screw is also a break-up
screw and used to adjust the distance of the spray.

SETTING THE ARC ADJUSTMENT

NOTE: The RPS gear driven sprinkler has a fixed right start 
and an adjustable left stop.

1

POSITIONING NOZZLE TURRET TO ITS “RIGHT START”

Place your finger on the top center of the nozzle turret.
Rotate the turret counter-clockwise to the left stop to
complete any interrupted rotation cycle. Rotate the nozzle
turret clockwise to the “right start.” This is the fixed side of
the arc. The nozzle turret must be held in this position for
arc adjustments. The “right start” does not change.

NOTE: The RPS is factory preset with a 180° arc setting, and includes a pre-installed #3 nozzle.

KEY IN KEYHOLE

NOZZLE
TURRET

NOZZLE
RETENTION
SCREW

NOZZLE
SOCKET

NOZZLE 
RETENTION
SCREW

KEYHOLE

ARC SET
ADJUSTMENT

NOZZLE TURRET TOP

NOZZLE

NOZZLE
PRONGS

LEFT 
STOP

RIGHT 
START

LEFT RIGHT 

UNIVERSAL TOOL

PULL UP KEY

FLAT BLADE 
SCREWDRIVER

ARC
ADJUSTMENT
KEY

HEX FOR
NOZZLE 
RETENTION 
SCREW

A

C

B

D

2

ADJUSTING THE RIGHT (FIXED) SIDE OF ARC

If the right side of the arc is not properly aligned, the sprinkler may spray in areas not intended for watering such
as driveways or adjacent properties. The right side arc can easily be realigned.

OPTION 1: REPOSITION CAN ON THE FITTING.
Turn the sprinkler can and the fitting below it left or right to the desired position. This may require temporary
removal of the soil around the sprinkler to allow you to grip the sprinkler can.

OPTION 2: REMOVE INTERNAL RISER ASSEMBLY AND REPOSITION.
Unscrew the top counter-clockwise and remove the internal riser assembly from the can. Once removed with
nozzle turret at its “right start,” reposition riser assembly so that nozzle arrow points to the desired start position.
Replace riser assembly back in the can and screw on the top.

At this point you have realigned the right arc stop, and you can adjust the left arc to an appropriate setting.

Содержание RPS Series

Страница 1: ...to the left stop to complete any interrupted rotation cycle Rotate the nozzle turret clockwise to the right start This is the fixed side of the arc The nozzle turret must be held in this position for arc adjustments The right start does not change NOTE The RPS is factory preset with a 180 arc setting and includes a pre installed 3 nozzle KEY IN KEYHOLE NOZZLE TURRET NOZZLE RETENTION SCREW NOZZLE S...

Страница 2: ...please note the following 1 Do not exceed 30 PSI 2 Always introduce air into the system gradually to avoid air pressure surges Sudden release of compressed air into the sprinkler can cause damage 3 Each zone should run no longer than 1 minute on air Sprinklers turn 10 to 12 times faster on air than on water Over spinning rotors on air can cause damage to the internal components INSTRUCCIONES DE AJ...

Страница 3: ...sario retirar el césped o la tierra del suelo alrededor del aspersor para permitirle sujetar la carcasa con la mano OPCIÓN 2 RETIRAR EL ENSAMBLAJE INTERNO DE LATURBINAYVOLVERLO A COLOCAR Desenrosque la tapa en el sentido contrario al de las agujas del reloj y saque de la carcasa el vástago con el muelle Una vez quitado y con la cabeza giratoria en la posición de inicio de arranque a la derecha vue...

Страница 4: ...dal KPa Bars Meters L M M3 H Bares Metros 207 2 0 6 7 4 5 34 275 3 0 7 3 6 4 39 344 3 5 7 9 6 8 41 413 4 0 8 5 7 6 46 207 2 0 8 8 11 4 68 275 3 0 9 8 11 7 71 344 3 5 10 7 13 2 80 413 4 0 11 3 14 4 87 207 2 0 9 4 12 9 78 275 3 0 10 4 14 8 89 344 3 5 11 3 16 7 1 00 413 4 0 11 6 17 8 1 07 275 3 0 11 6 24 6 1 68 344 3 5 12 2 27 6 1 66 413 4 0 12 8 30 3 1 82 482 5 0 13 4 32 6 1 96 U S Nozzle Pressure R...