www.krain.com
TROUBLESHOOTING
23
PROGRAM
DOES NOT
COME ON
AUTOMATICALLY
DISPLAY SHOWS
A STATION IN
OPERATION BUT
NO WATERING
OCCURS
Dial set to the OFF position
No Start Time
Permanent Day Off
Feature is Active
No Primary AC Power
Today may not be a
Scheduled Watering Day
Active or Faulty Rain Sensor
No Primary AC Power
An Open Circuit in the Valve
Solenoid or Wiring has
disabled the station (Open
Circuit Feature has been
disabled – page 12)
Rain Sensor is Active and
preventing watering
Sensor Jumper is missing
Set dial to AUTO
Turn the dial to PROGRAM DISPLAY check
program for start time(s). If missing turn dial
to SET PROGRAM START TIMES and enter
a start time(s) if needed (page 5).
Change permanent day programming
if needed (page 14).
Restore primary AC power.
Turn the dial to PROGRAM DISPLAY and check program
Watering Day(s). If missing turn the dial to SET WATERING
DAYS and enter watering day(s) if needed (page 6).
Check LCD Display for BYPASSED or SENSOR.
Set Rain Sensor Switch to the Bypassed position.
Restore primary AC power.
Locate and repair.
Turning ON the Open Circuit Feature will prevent
station operation when the valve solenoid or wiring
has disabled the station (page 12).
If a recent rain event has occurred
then no action is required.
Place Rain Sensor Switch in the BY PASSED position
to resume operation. If watering does not resume the
Rain Sensor is not operating properly.
Replace Jumper
SYMPTOM POSSIBLE CAUSE CORRECTION