Operation & Calibration
33
Figure 3-14: Mode 1-Simple Gated-Event Calculation
Mode 2: Single Period Measurement
The counter calculates the period of the signal on GPTC_GATE in terms
of GPTC_CLK. The initial count can be loaded from the software applica
-
tion. After software start, the counter calculates the number of active
edges on GPTC_CLK between two active edges of GPTC_GATE. After the
completion of the period interval on GPTC_GATE, GPTC_OUT outputs
high and then current count value can be read by the software applica
-
tion. Operation in which initial count = 0, count-up mode is shown.
Figure 3-15: Mode 2-Single Period Measurement
Mode 3: Single Pulse-Width Measurement
The counter calculates the pulse-width of the signal on GPTC_GATE in
terms of GPTC_CLK. Initial count can be loaded from the software appli
-
5
5
4
3
2
1
1
0
ffff
Gate
CLK
Count value
Software start
0
0
1
2
3
4
5
5
5
Gate
CLK
Count value
Software start