1-50 (No.MB496)
Press the [3] key ,[STOP ] key
and [power] key on the remote controller.
(Press the [3] key ,[STOP ] key and [POWER] key on the remote controller,
it will become the read-out mode of the error log.)
Press the [3] key ,[STOP ] key
and [power] key on the remote controller.
(2) Written to ER R O R
No
Item
Writing
times
Writing contents
Writing conditions
writing SAFETY number and AD value
SAFETY number
and AD value
Factor of failure
1 SAFETY Number
16
Power circuit failure.
Damage of card wire.
Missing key operation.
Damage of card wire.
Missing key operation.
AD value
16
2 Timer playback is not starting
Timer playback is not starting
Timer recording is not starting
Timer recording is not starting
16
Factor of failure
Factor of failure
Factor of failure
Factor of failure
Factor of failure
Factor of failure
Factor of failure
Factor of failure
Factor of power OFF
User operation
User operation
User operation
User operation
3
16
4 Recording is not starting
Normal recording is not starting
16
5
Time out power OFF
16
6 CD
16
Error with CD
Error with DVD
Error with MD
Error with TAPE
7 DVD
16
Mechanical failure
Mechanical failure
Mechanical and pick up failure
Mechanical and module failure
Mechanical and module failure
8 MD
16
9 TAPE
Power OFF
16
10
16
When starting of power OFF process
When detecting of SAFETY error,
Time out of power OFF process
Starting address is the 00.
byte display.
FL display
ERR INFO
FL display
address 00
data 01
Press the [SKIP ] key, Increase and decrease the lower address.
Press the [GULP SKIP ] key, Increase and decrease the ten column address.
Pressing the
Pressing the
Pressing the
Pressing the
Example:
Operation
Display
address
data
Pressing the
key
key
key
key
key
Normal function display
The contents of ERROR are written in the EEPROM address.
(3)The error log check method
Read-out of a error history can be displayed by code of remote control at the time of POWER ON and OFF of a set.
4. Error history
(1) Outline
The failure that is not reproduced may occur in a market.
Presumption of the cause of failure is difficult.
This error log is recorded when failure occurs.
It is displayed again and can use to service.
Using the EEPROM of 256bytes.
When an unusual state occurs, it writes the factor in EEPROM.
It leaves the history for 16 times to each item.
The error log displays in TEST code of remote controller,
and enables it to check the contents of each address by the key.
(except TIMER RECORDING)
01
10
0F
00
F0
05
21
11
01
00
:
:
:
:
: