(No.MB496)1-47
(7) Setup of the TEST MODE 2
Setup is complete.
Press the [POWER] key on
the main unit.
While pressing both the [STOP ] key
and [MD PLAY ] key on the main unit,
insert the AC power cord in an outlet.
FL display
MD TEST
Press the [STOP ] key and
[MD EJECT ] key on the main unit
at the same time.
FL display
MD TEST 2
FL display
MD TEST 2
1. Quantity of change display of pickup adjustment value
Only the TOC reading end back becomes effective.
1. C1 errer display
Only the TOC reading end back becomes effective.
Press the [6] key on the
remote controller.
FL display
MD TEST 2
FL display
####:
: Adjustment value
####: Refer to the status table.
Quantity of change display
Status table
FL display
LPOW
Laser power, Premastered disc=0, Recordable disc=recordable power
(There is temperature revision)
ASGN
TGAN
Status contents
AS gain adjustment value
Tracking gain adjustment value
TBAL
Tracking balance adjustment value
FBAL
Focus balance adjustment value
FRGN
Focus loop gain adjustment value
TRGN
Tracking loop gain adjustment value
NRFD
NRFDET threshold value
LPGN
Lens position servo gain adjustment value
FL display
MD TEST 1
Next status display.
Press the [STOP ] key
on the remote controller.
Press the [8] key on the
remote controller.
FL display
MD TEST 2
(8) Cancel of the TEST MODE
To cancel the test mode, press the [POWER] key on the main unit.
display is finished.
The command A1 to 01 is transmitted
for every ten seconds.
The command is transmitted
in order of A1 to 00.
FL display
-
-
-
Repeats 432 time .