Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
NT SC 3.58
PHASE
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
#
)
[CRT SOCKET
PWB]
S05 (NT SC PHASE)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
#
).
3. Select the SIGNAL BLOCK from SERVICE
MENU.
4. Select the S05 item.
5. Adjust the S05 to become the v oltage different
between 75% white and magenta to 0V
±
2Vp-p
as s hown in figure.
Comp onent
signal
CHROMA
adjustment
Comp onent / RGB
input card
(IF-C01COM)
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
#
)
[CRT SOCKET
PWB]
S06 (NT SC PHASE)
[SERVICE MENU]
1. Turn off the main power s witch on the rear panel.
2. Ins ert the component / RGB input card to the rear
slot.
3. Input the colour bar signals (Y, B-Y, R-Y) to each
terminal of the c omponent / RGB input card.
4. Select the “INPUT D” by the front panel switch.
5. Connect the oscillo-scope probe to TP-47B and
TP-E(
#
).
6.
Select the SIGNAL BLOCK from SERVICE
MENU.
7. Select the S06 item.
8. Adjust the S06 to become the voltage different
between 75% white and blue to
0V
±
±
±
±
2Vp-p
as
shown in figure.
0V
±
±
±
±
2V
BL
B
R
Mg
G
Cy
Y
W
75%
0V
±
±
±
±
2V
BL
B
R
Mg
G
Cy
Y
W
75%