No.51961
TM-H1950CG
28
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
White
Balance
(High light)
9300K
adjustment
Signal generator
(Monoscope pattern)
Colour t emperature
meter or Colour
An alyser
W06 R DRIVE
W07 B DRIVE
[SERVICE MENU]
Finish the adjustment of low light c ompletely first in
advanc e of this adjustment.
1. Input the mono-sc ope pattern signal .
2. Select the WHITE BALANCE BLOCK mode from
<BLOCK SELECT> screen.
3. Select the 9300 DRIVE adjustment mode (High
light 9300 mode).
4. Apply the sensor of the colour temperature meter
to the CRT surfac e, portion of the 100% white,
adjust the W06 (R DRIVE) or W07 (B DRIVE) to
setting 9300K (x=0.283, y=0.297).
5. Exit the SERVICE MENU by pressing the “EXIT”
key.
6. Check the white balance tracking is finest when
CONTRAST and BRIGHT are up and down.
Bright
adjustment
Signal generator
(Sprit colour b ar)
S01 (BRIGHT)
[SERVICE MENU]
Finish the adjustment of low light completely first in
advanc e of this adjustment.
1. Input a s prit colour bar signal.
2. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
3. Select the S01 item.
4. Adjust the S01 to where the sprit colour bar 0%
blac k component not to brightens.
5. Check it to on and off the screen display by
turning the “DISP” switch.
Contrast
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47G
TP-E(
#
)
[CRT SOCKET
PWB]
S02 (CONTRAST)
[SERVICE MENU]
1.Input the full colour bar signal. (75 / 0 / 75 / 0 set-
up level s ignal)
2.Connect the oscillo-scope probe to TP-47G and
TP-E(
#
).
3.Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4.Select the S02 item.
5.Adjust the S02 to become the voltage different
between 75% white and 0% black to
37V
±
±
±
±
2Vp-p
as shown in figure.
V
75-BL
=(37
±
±
±
±
2)V(p-p)
BL
B
R
Mg
G
Cy
Y
W
75%
WHITE