No.51921
TM-A101G
26
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
Bright
adjustment
Signal generator
(Sprit colour bar)
S01 (BRIGHT)
[SERVICE MENU]
xxxx
Under the condition that Low light adjustment
has been correctly finished.
1. Input a sprit colour bar signal.
2. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
3. Select the S01 item.
4. Adjust the S01 to where the sprit colour bar 0%
black component faintly brightens.
5. Check it to on and off the screen display by
turning the “DISP” switch.
Contrast
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47G
TP-E(
)
[CRT SOCKET
PWB]
S02 (CONTRAST)
[SERVICE MENU]
1. Input the full colour bar signal. (75 / 0 / 75 / 0
set-up level signal)
2. Connect the oscillo-scope probe to TP-47G and
TP-E(
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S02 item.
5. Adjust the S02 to become the voltage different
between 75% white and 0% black to
30V
Ѱ
Ѱ
Ѱ
Ѱ
2Vp-p
as shown in figure.
PAL CHROMA
Saturation
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S03(PAL CHROMA)
[SERVICE MENU]
1. Input a PAL full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S03 item.
5. Adjust the S03 to become the voltage different
between 75% white and blue to
0V
Ѱ
Ѱ
Ѱ
Ѱ
2Vp-p
as
shown in figure.
V
75-BL
=(30 2)Vp-p
BL
B
R
Mg
G
Cy
Y
W
75%
WHITE
0V
2V
BL
B
R
Mg
G
Cy
Y
W
75%