No.51921
TM-A101G
24
ADJUSTMENT
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
Checking of
the B1 power
supply
DC Voltmeter
TP-91(B1) :
(S1
Ο
Ο
Ο
Ο
pin)
TP-E(GND) :
(S1
Σ
Σ
Σ
Σ
pin)
[MAIN PWB]
SCREEN VR
[Lower knob :
in FBT]
1. Set power supply voltage to
AC230V
Ѱ
Ѱ
Ѱ
Ѱ
5V
(TM-
A101G
/E
) /
AC120V
Ѱ
Ѱ
Ѱ
Ѱ
5V
(TM-A101G
/U
).
2. Select WHITE BALANCE BLOCK mode from
<BLOCK SELECT> screen.
3. Select CUTOFF adjustment mode (Low light
mode).
4. Press “SERV” switch to display the horizontal
line.
5. Adjust the SCREEN VR to disappear the
horizontal line.
6. Check the B1 voltage as
114.8V
Ѱ
Ѱ
Ѱ
Ѱ
2V
.
7. Readjust the SCREEN VR to appear the
horizontal line faintly, and cancel the horizontal
line to press the “SERV” switch.
Checking of
the High
voltage
High voltage meter
CRT Anode
SCREEN VR
[Lower knob :
in FBT]
1. Set power supply voltage to
AC230V
Ѱ
Ѱ
Ѱ
Ѱ
5V
(TM-
A101G
/E
) /
AC120V
Ѱ
Ѱ
Ѱ
Ѱ
5V
(TM-A101G
/U
).
2. Select WHITE BALANCE BLOCK mode from
<BLOCK SELECT> screen.
3. Select CUTOFF adjustment mode (Low light
mode).
4. Press “SERV” switch to display the horizontal
line.
5. Adjust the SCREEN VR to disappear the
horizontal line.
6. Connect the high voltage meter to the CRT
anode and check it as
21.0
ϡ
ϡ
ϡ
ϡ
23.0kV
.
7. Readjust the SCREEN VR to appear the
horizontal line faintly, and cancel the horizontal
line to press the “SERV” switch.
Focus
adjustment
Signal generator
(Resolution pattern)
FOCUS VR
[Upper knob :
in FBT]
1. Input the resolution pattern signal.
2. Adjust the Focus VR for optimum focus where
moire is not apparent.
3. Darken the picture and adjust the focus by
turning counter-clockwise from the position
where focus is poor.
4. Alternately repeat the above steps to obtain the
optimum position.