8
2.5 Adjusting the Camera Position
The dome camera has three axes for positioning the camera. While monitoring the
picture on the monitor, adjust the camera position as follows:
Horizontal Adjustment
Rotate 3D assembly in the base. Do not turn assembly
more than 360° as this may cause the internal cables to twist and disconnect or
break.
Before making horizontal adjustment, please adjust vertical adjustment to 90
degree (vertical) first.
Vertical Adjustment
After loosening the screw on the bracket, position the camera
as desired, then tighten the screw back to the bracket.
Horizontal Rotation
For wall mount and tilted ceilings, rotate the lens base
(maximum 360°) until you are satisfied with the field of view.
1. Rotate 3D assembly in base for
horizontal adjustment
2. Tilt adjustment bracket and screw
for vertical adjustment
3. Axis ring for horizontal rotation
for wall mount and tilted ceilings
Figure 2-4 Camera adjustment
2.6 Adjusting the Lens
1. Loosen the focus lever counter-clockwise a little, then adjust the focus for
optimum picture sharpness.
2. Loosen the zoom lever counter-clockwise a little, then rotate the zoom lever and
determine the image view.
3. Re-tighten the zoom lever and focus lever after adjustment.
Note:
It is important that you lock the
zoom
and focus levers after making
adjustments. This will avoid the positions moving (for example, from temperature
changes or vibrations).