1-20 (No.MA467<Rev.002>)
4.7
DC OFFSET ERROR INFORMATION
4.7.1 Display indication
4.7.2 Error content confirmation.
Whether it turns on power and the "PROTECT" display appears are confirmed.
(1) When the "PROTECT" display appears.
The content of the DC offset error is confirmed in the Service mode.
* Because it takes DC offset protection, the following is displayed.
"DC ERROR"
(1-1) When "DC1 ERROR" is displayed. (DC ERROR1)
•Forecast cause
It comes in contact with improper connection or GND of the speaker wiring.
It is confirmed that there is no improper connection of the speaker wiring and pushes reset.
•When "PROTECT" is not displayed, it is unquestionable.
The error data of EEPROM, it deletes it. (CLR DC1)
•When "PROTECT" is still displayed.
The DC offset has been generated by the reasons other than the improper connection.
Forecast cause: Power AMP is broken.
After parts are exchanged, reset is confirmed pushing again.
(1-2) When "DC2 X" is displayed. (DC ERROR2)
* As for X, the detected number is displayed. (0-4)
* When X is 0, it is unquestionable because the DC offset has never been detected.
When leak of capacitor is detected, it is displayed.
It is confirmed that there is no problem in the capacitor and deletes the error data of EEPROM. (CLR DC2)
It is confirmed that reset is pushed and "PROTECT" is not displayed.
After above-mentioned (1-1) and (1-2) are executed, the conect of the DC offset error is confirmed in the Service mode.
If the part displayed as "DC ERROR" becomes "DC OK", it is unquestionable.
(2) When the "PROTECT" display doesn't appear.
The content of the DC offset error is confirmed in the Service mode.
(2-1) When "DC OK" is displayed, it is unquestionable because the DC offset has not been detected in the past.
(2-2) When "DC ERROR" is displayed, the confirmation similar to (1-1) and (1-2) is done because there is a history that detected
the DC offset error in the past.
DC OK
DC ERROR
CLR DC1 VOL push to confirm
DC 1 OK
DC 1 ERROR
DC 2 X
BACK
VOL
push
VOL
knob
BACK
VOL
push
CLR DC2 VOL push to confirm
BACK
VOL
push