(No.YA061)1-27
4.8.5 VSM PRESET SETTING
SUB HUE-2
Signal
generator
Oscilloscope
Remote
control unit
TP-47B
TP-E
[CRT SOCKET
PWB]
[2.V/C]
7.HUE
[Method of adjustment using measuring instrument]
NTSC 3.58 HUE
(1) Input the NTSC 3.58MHz signal (full field colour
bar with 75% white) from the EXT terminal.
(2) Set the ZOOM mode to FULL.
(3) Set the PICTURE mode to STD.
(4) Select 2.V/C from the SERVICE MENU.
(5) Select < 7. HUE >.
(6) Set the initial setting value of < 7. HUE >.
(7) Connect the oscilloscope between TP-47B and
TP-E.
(8) Adjust < 7. HUE > to bring the value of (B) in the
illustration to the values as shown given billow
(voltage difference between white (W) and
magenta (M)).
(9) Press the [MENU] key and memorize the set
value.
NTSC 4.43 HUE
(1) When NTSC 3.58 COLOUR set, NTSC 4.43
COLOUR will automatically set.
Item
Measuring
instrument
Test point
Adjustment part
Description
W
M
0V
(-)
(+)
(B)
Y
C
G
R
B
VOLTAGE (W-M)
-3V
[VOLTAGE SETTING]
Voltage setting
Item
Measuring
instrument
Test point
Adjustment part
Description
VSM PRESET
Remote
control unit
[5.VSM PRESET]
(BRIGHT/STD/SOFT)
1. BRIGHT
2. CONT.
3. COLOUR
4. SHARP
5. HUE
(COOL/WARM/NORMAL)
1. R DRIVE
2. G DRIVE
3. B DRIVE
(1) Set the ZOOM mode to FULL.
(2) Select 5.VSM PRESET from the SERVICE MENU.
(3) Press the [MENU] key, and set the PICTURE MODE
to BRIGHT.
(4) Adjust the [FUNCTION UP/DOWN] and [-/+] key to
bring the set values of 1.BRIGHT to 5. HUE to the
values shown in the [5. VSM PRESET].
(5) Press the [MENU] key, and set the PICTURE MODE
to STD.
(6) Make similar adjustment as in 3 above.
(7) Press the [MENU] key, and set the PICTURE MODE
to SOFT.
(8) Make similar adjustment as in 3 above.
(9) Press the [MENU] key, and set the COLOUR TEMP
to COOL.
(10) Adjust the [FUNCTION UP/DOWN] and [-/+] key to
bring the set values of 1. R DRIVE to 3. B DRIVE to
the values shown in the table.
(11) Press the [MENU] key, and set the COLOUR TEMP
to WARM.
(12) Make similar adjustment as in 9 above.
(13) Press the [MENU] key, and set the COLOUR TEMP
to NORMAL.
(14) Make similar adjustment as in 9 above.