4.8
ADJUSTMENT PROCEDURE
4.8.1 CHECK ITEM
Item
Measuring
instrument
Test point
Adjustment part
Description
B1 POWER
SUPPLY
check
Signal
generator
DC voltmeter
Remote
control unit
X connector
TP-91(B1)
TP-E
[POWER DEF
PWB]
[2.V/C]
12.RGB BLK
(1) Receive the any broadcast.
(2) Select 2. V/C from the SERVICE MENU.
(3) Select < 12. RGB BLK >.
(4) Press the [FU (
)] key to find the cut off
screen (Black screen).
(5) Connect a DC voltmeter to TP-91(B1) and TP-E.
(6) Make sure that the voltage is DC143V ± 2.0V.
(7) Press the [FUNCTION - (
)] key to return to service
menu.
HIGH VOLTAGE
check
Signal
generator
HV voltmeter
Remote
control unit
CRT anode
Chassis GND
[2.V/C]
12.RGB BLK
(1) Receive the any broadcast.
(2) Select 2. V/C from the SERVICE MENU.
(3) Select < 12. RGB BLK >.
(4) Press the [FU (
)] key to find the cut off
screen (Black screen).
(5) Connect a HV voltmeter to CRT ANODE and
chassis GND.
(A ground side is connected previously)
(6) Make sure that the voltage is DC 31.0kV
(+1kV / -1.5kV).
(7) Press the [FUNCTION - (
)] key to return to service
menu.
NOTE:
When removing a prove, an anode side is removed
previously.
IF VCO
check
Remote
control unit
[1.IF]
1.VCO
• Under normal conditions, no adjustment is required.
• It must not adjust without broadcast signal.
(1) Receive the any broadcast.
(2) Select 1.IF from the SERVICE MENU.
(3) Select < 1.VCO >.
(4) Check the
←
(arrow) position between the ABOVE
REF. and BELOW REF.
1. VCO
2. DELAY POINT
IF SERVICE MENU
TOO HIGH
ABOVE REF
JUST REF
BELOW REF
TOO LOW
VCO(CW)
**** MHz
Do not move