PURITY, CONVERGENCE ADJUSTMENT
PURITY ADJUSTMENT
1. Demagnetize CRT with the demagnetizer.
2. Loosen the retainer screw of the deflection yoke.
3. Remove the wedges.
4. Input a green raster signal from the signal generator, and turn
the screen to green raster.
5. Move the deflection yoke backward.
6. Bring the long lug of the purity magnets on the short lug and
position them horizontally. (Fig.2)
7. Adjust the gap between two lugs so that the GREEN RASTER
will come into the center of the screen. (Fig.3)
8. Move the deflection yoke forward, and fix the position of the
deflection yoke so that the whole screen will become green.
9. Insert the wedge to the top side of the deflection yoke so that it
will not move.
10. Input a crosshatch signal.
11. Verify that the screen is horizontal.
12. Input red and blue raster signals, and make sure that purity is
properly adjusted.
P : PURITY MAGNET
4 : 4 POLES
(convergence magnets)
6 : 6 POLES
(convergence magnets)
Fig.1
Fig.3
Fig.2
PURITY MAGNETS
Long lug
Short lug
Bring the long lug over the short lug
and position them horizontally.
(FRONT VIEW)
GREEN RASTER
CENTER
WEDGE
DYNAMIC CONVERGENCE ADJUSTMENT
P / C MAGNETS
4 6
CRT
DEF. YOKE
CRT SOCKET PWB
PURITY MAGNET(P)
P/C MAGNETS
Содержание HV-L29PRO
Страница 36: ...No 51828 HV L29PRO 36 MC Service ...
Страница 57: ...No 51828 HV L29PRO 56 PACKING 5 4 7 9 10 11 8 2 2 12 6 13 3 3 A AU EE 14 1 ...
Страница 59: ...No 51828 HV L29PRO 58 Memo ...
Страница 60: ...No 51828 HV L29PRO 59 Memo ...
Страница 66: ...HV L29PRO HV L29PRO No 51828 No 51828 2 11 2 12 100Hz PWB CIRCUIT DIAGRAM 100Hz PWB SMF0Z501A H2 MC Service ...
Страница 72: ...HV L29PRO HV L29PRO No 51828 No 51828 PATTERN DIAGRAMS MAIN PWB PATTERN FRONT 2 23 2 24 MC Service ...
Страница 73: ...HV L29PRO HV L29PRO No 51828 No 51828 FRONT TP 91 B1 TP E POWER DEF PWB PATTERN 2 25 2 26 MC Service ...
Страница 76: ...HV L29PRO HV L29PRO No 51828 No 51828 2 31 2 32 TOP AV SW PWB PATTERN TOP CRT SOCKET PWB PATTERN MC Service ...