No. 51828
HV-L29PRO
22
VSM PRESET SETTING
Item
Measuring
instrument
Test point
Adjustment part
Description
Setting of
VSM PRESET
Remote
control unit
1.CONT.
2. BRIGHT
3. SHARP
4. COLOUR
5. TINT
1. Select 5.VSM PRESET from the SERVICE MENU.
2. Select STD with the PICTURE MODE key of the remote control
unit.
3. Adjust the function UP/DOWN and LEFT/RIGHT key to bring
the set values of 1.CONT
~
5. TINT to the values shown in
the table.
4. Press the MENU/OK key and memorize the set value.
5. Respectively select the VSM PRESET mode for REGULAR
and BRIGHT, and make similar adjustment as in 3 above.
6. Press the MENU/OK key and memorize the set value.
#
Refer to OPERATING INSTRUCTIONS for the PICTURE
MODE.
Setting item
VSM preset mode
1. CONT.
2. BRIGHT
3. SHARP
4. COLOUR
5. TINT
BRIGHT
+16
0
-10
+3
0
STANDARD
+7
0
-10
0
0
SOFT
0
0
-12
-2
0
SETTING VALUES OF VSM PRESET
Содержание HV-L29PRO
Страница 36: ...No 51828 HV L29PRO 36 MC Service ...
Страница 57: ...No 51828 HV L29PRO 56 PACKING 5 4 7 9 10 11 8 2 2 12 6 13 3 3 A AU EE 14 1 ...
Страница 59: ...No 51828 HV L29PRO 58 Memo ...
Страница 60: ...No 51828 HV L29PRO 59 Memo ...
Страница 66: ...HV L29PRO HV L29PRO No 51828 No 51828 2 11 2 12 100Hz PWB CIRCUIT DIAGRAM 100Hz PWB SMF0Z501A H2 MC Service ...
Страница 72: ...HV L29PRO HV L29PRO No 51828 No 51828 PATTERN DIAGRAMS MAIN PWB PATTERN FRONT 2 23 2 24 MC Service ...
Страница 73: ...HV L29PRO HV L29PRO No 51828 No 51828 FRONT TP 91 B1 TP E POWER DEF PWB PATTERN 2 25 2 26 MC Service ...
Страница 76: ...HV L29PRO HV L29PRO No 51828 No 51828 2 31 2 32 TOP AV SW PWB PATTERN TOP CRT SOCKET PWB PATTERN MC Service ...