27
<Functions controlled by the MAKE/TRIGGER system>
Display
Functions to be controlled
Opening
Short-circuiting
TALLY SEL
Selects the color of the tally lamp
Green
Red
SDI 1/L
Changes the input to “SDI 1/L”
Invalid
Valid
SDI 2/R
Changes the input to “SDI 2/R”
Invalid
Valid
DVI
Changes the input to “DVI”
Invalid
Valid
3D
Activates/Deactivates the 3D mode
Off
On
MIX
Activates/Deactivates the MIX mode
Off
On
3D FORMAT
3D format 1/3D format 2 change
*3
FORMAT1
FORMAT2
3G-B.DS
Selects the data stream of “3G SDI LEVEL B”
DS1
DS2
DUAL LINK
Turns on or off “SDI DUAL LINK”
Off
On
MARKER
Displays the area and safety markers
Off
On
FRAME
Indication of the area of the specified aspect ratio
Off
On
C.MARKER
The center marker indication
Off
On
MARK.SEL
Selects the items of “MARKER”
*4
Non-“R-” items
“R-” items
ASPECT
Changes the aspect ratio
4:3
16:9
1:1
Displays in 1:1 mode
Off
On
STATUS
Status display
*5
→
“On the Status Display” on page 11
L.METER
Audio level meter display
*6
TIME CODE
Time code display
Off
On
SOURCE ID
→
“SOURCE ID” in “INFORMATION” on page 24
*7
PARA.WFM
Displays the wave form monitor (Normal or Parallel)
*8
PARA.VS
Displays the vector scope (Normal or Parallel)
BAL.WFM
Displays the wave form monitor (Normal or Difference)
BAL.VS
Displays the vector scope (Normal or Difference)
COLOR OFF
Color off
Color
Monochrome
SCR CHECK
Screens check
*9
I/P MODE
Change a mode according to the input picture
*10
MUTING
Muting on/off
Off
On
DIMMER
Change the intensity of the button lamps
NORMAL
DARK
−−−
No function
—
—
*3
The 3D format changes in the same way as the SELECT button pressed in 3D mode.
*4
Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items (
→
“MARKER” on page 20).
*5
Displays the information shown when INPUT SELECT button of the current input is pressed (
→
“On the Status Display” on page 11). While
controlling with the MAKE system, the information is displayed only at the moment of short-circuiting.
*6
While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and hidden (opening). When
“LEVEL METER ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT” appears). While controlling with the TRIGGER system, the
pattern of the audio channel display is switched.
*7
While controlling with the MAKE system, the available set-up options will be the setting value currently selected in “SOURCE ID” (“ON” or
“AUTO” [short-circuiting]) and “OFF” (opening). While controlling with the TRIGGER system, uses the same set-up option as those in the SET-
UP MENU (
→
“SOURCE ID” in “INFORMATION” on page 24).
*8
While controlling with the TRIGGER system, the display mode changes in the same way as for the normal SCOPE function. (
→
e
on page 9)
While controlling with the MAKE system, the displayed (short-cirtuiting)/hidden (opening) operations are performed as follows regardless of
the MAIN MENU “AUTO OFF” setting:
[PIN 1] − [PIN 5] settings
Priority when the settings a re configured simultaneously
Display
PARA.WFM PARA.VS
BAL.WFM
BAL.VS
MIX
mode
Invalid
Wave form
monitor
Vector
scope
Wave form
monitor
Vector
scope
Wave form monitor > Vector scope
Valid
Parallel
wave form
monitor
Parallel
vector
scope
Difference
wave form
monitor
Difference
vector
scope
Parallel wave
form monitor
>
Difference wave
form monitor
>
Parallel
vector scope
>
Difference
vector scope
*9
While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen (short-circuiting). While
controlling with the TRIGGER system, the screen changes in the same way as when pressing SCREENS CHECK button (
→
w
on page 9).
*10
Must be controlled with the TRIGGER system. The mode changes in the order of “NORMAL”
→
“CINEMA”
→
“FIELD” (This function cannot be
controlled with the MAKE system).
●
You cannot assign the same function to different pin terminals.
●
The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and opening it.
DT3D24G1̲EN.indb 27
DT3D24G1̲EN.indb 27
11.1.25 0:53:55 PM