J
USTCHLOR OWNERS HANDBOOK
Page 3 of 16
Created by: Product Management – Just Range of Products – Jasco Trading (Pty) Ltd
2.3. Mount the Power Pack so that it will be accessible and visible for easy maintenance
and ensure that the meter is in the vertical position. Should it be necessary to mount
the Power Pack outside the Pump/filter box, then, it must be protected from the
elements especially R
ain and the Garden Irrigation System.
Your warrantee will
lapse in the event of water damage.
2.4. The power pack generates heat and must be afforded the opportunity to breathe.
The underside of the unit is well ventilated and must not be obstructed, neither
should the side vents.
3. Installing the Electrolytic Cell
3.1. The Element Assembly (Electrode and Housing), must be the last item in the water
return line (after the pool heating system if so equipped) and must be installed
vertically. Do not let anyone tell you otherwise.
Refer to Diagram 1 below
.
3.2. When selecting your position, bear in mind, accessibility and maintainability. (i.e.
Ease of extraction of the cell for maintenance). In cases where the system is below
water level - ensure that a non-return valve is installed between the cell housing and
the return to the pool. If neglected - flooding of the cell/pump area and drainage of
the pool will ensue once maintenance of the cell is attempted.
3.3. It is advised that you use universal unions to couple the electrode housing into the
pipe work and multi-port valve, This allows you to, to repair or replace the multi-port
valve, with ease and without the need to “cut” into the plumbing, should the need
arise.
3.4. The element itself is then screwed into positioned within the casing, requiring
approximately 1.7 turns to seal it in position.
3.5. The cables that connect the element to the power pack should not need to be
disconnected for any reason whatsoever, there is a high current passing through
these connections and interference with the connections fitment can result in the
system malfunctioning.
Diagram 1
4. Electrical
Connection
4.1. Ensure the Pool pump and
JustChlor
®
Power Pack is connected to the same power
source i.e. The Pool Pump Timer (especially the self cleaning models).