Elektroapparate AG
Technical information
Technical Support
Language
EN
Z6 One Touch TFT
Author: Patrik Studer
Checked:
Approved:
Docu.-name:
Technische_Informationen_Z6_OT_TFT_EN.docx
L:\Geräte\Linie_Z_Neu\Z6_OT_TFT\Schulungsunterlagen\E\T
echnische_Informationen_Z6_OT_TFT_EN.docx
Date:
Rev. A:
Rev. B:
Rev. C:
Rev. D:
Rev. E:
Rev. F:
30.04.2015
Page 16/16
14
Error messages:
If there is a malfunction, an error message as described below is shown on the display:
The appliance switches-OFF automatically 5 sec. after an ERROR occurred
Details see in Service binder (sheet Error messages)
Display
Designation
ERROR 1
COFFEE: Temperature sensor notify “value below tolerance”
ERROR 2
COFFEE: Temperature sensor notify “value above tolerance”
ERROR 5
Heating up not possible
ERROR 6
“Positioning” / “Initialisation” of multivalve not possible
ERROR 8
“Positioning” / “Initialisation” of brewing unit not possible
ERROR 9
Logic relay is defective
ERROR 10
Heating was too hot (mains interferences received)
ERROR 15
Initialisation of CAPPU stepper motor not possible
ERROR 22
CLARIS Smart communication problem
ERROR 23
Controller timeout (Logic <-> Display)
15
Accessory:
Milk Control Wireless supported
JURA automatic filling device not supported