Installation Instructions
For Juno TLR95 and TLR96 Cable Feed and Mechanical Support
Important Safety Instructions-Save these Instructions
Read all of these installation instructions before installing the trac system.
Do not install this trac in damp or wet locations.
Do not install any fixture assembly closer than 6" from any curtain or similar combustible material.
Disconnect electrical power before adding to or changing the configuration of the trac.
Do not attempt to energize anything other than lighting fixtures on the trac. To reduce the risk of fire or electrical shock, do not attempt to
connect power tools, extension cords, appliances and the like to the trac.
Power to this trac system is to be supplied by either Juno 12V transformers (TL544N, TL547 (remote mounted only], TL548, TL549, TL550,
TL554, TF5150, TF5300, TF5300-277, TF5600, TF5600-277, TF6150E, TF6300) or 24V transformers (TL551, TL552, TL553, TF5600-24V, TF5600277-
24V, TF51200-24V, TF51200277-24V). Check with a qualified electrician before wiring trac. If 25 amps is exceeded anywhere in the
installed trac system, an overload will occur, resulting in a potential fire.
These mounting kits are to be used with Juno TLR series trac systems only. Use only fixtures intended for use with Juno TL or TLR series trac.
Save these instructions and refer to them when additions to or changes in the trac configuration are made.
T
LR95
Adjustable Stainless Steel Cable Mechanical Support Kit
Provides mechanical support to Trac12/25 with an adjustable stainless steel cable. TLR95
is compatible with most standard 15/16” exposed tee ceiling suspension systems
(using either flush or drop ceiling tiles) or a drywall ceiling.
NOTE:
The total number of cable suspension kits per section of trac must be as follows:
* 2’ (TLR2)
,
4’ (TLR4)
and 6' (TLR6)
require 2 pendant mounting kits per section of trac.
* 8’ (TLR8) require
s
3 pendant mounting kits per section of trac.
1.
Based on Figure 1, select the TLR95 components that correspond to the current
application (note: all parts in kit will not be used).
2.
Determine where the mounting kit will be installed, and mark the mounting surface or
T-bar.
3.
Based on the application, choose one of the following:
Grid Mounting:
*
Put the chosen screw through the hole in the T-bar grid clip (verify screw rotation is
prevented by the forms in the T-bar grid clip). Snap the T-bar grid clip / screw
assembly over the marks from step 2, and rotate until the grid clip locks into place.
(see figure 2)
*
If using the TLR95 with a drop ceiling tile, thread the #10-32 nut about halfway onto the
installed T-bar grid clip / screw assembly (reference figure 1). Push the canopy over
the screw until it stops on the #10-32 nut; adjust the height of the #10-32 nut until the
canopy sits flush with the bottom of the ceiling tile.
*
Push the canopy over the installed grid clip / screw assembly, and secure in place with
the nylon nut.
(continued on page 2)
WARRANTY
Juno warrants that its products are free from defects in material and workmanship. Juno’s obligation is expressly limited to repair or replacement, without charge, at Juno’s factory
after prior written return authorization has been granted. This warranty shall not apply to products which have been altered or repaired outside of Juno’s factory. This warranty is in lieu
of all other warranties, express or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantability. Also, there are no warranties
which extend beyond the description of the product on the company’s literature setting forth terms of sale.
Product Services phone (888) 387-2212
© 2003 Juno Printed in USA Juno lighting, inc 1300 S. Wolf Road Des Plaines, IL 60017 Visit us at www.junolighting.com
Trac 12/25
P2510 Pg 1 of 4
Figure 2
Flush Tile
3/8” Screw
(Silver)
11/16” Screw
(Black)
Grid Clip
Grid Clip
Toggle Wing
Nylon Nut
Canopy
3” Bolt
Drywall
Canopy
Canopy
Nylon Nut
Figure 1
#10-32 Nut
T
LR95
Configuration
Diagram
Flush
Ceiling Tile
Drop
Ceiling Tile
Rigid
Ceiling