1300 S. Wolf Rd • P.O. Box 5065 • Des Plaines, IL 60017-5065 • Phone: 847-827-9880 • www.
j
unolighting.com
lighting inc.
¤
®
Trac 12/25
P2510
Pg 3 of 4
TLR96
Adjustable Stainless Steel Cable Feed & Mechanical
Support
Provides an electrical connection to trac with a 10ga clear
tandem cord from a remote mounted low voltage transformer
when mounted to a J-Box. The TLR96 also provides mechanical
support of trac via stainless steel cable.
Notes:
* The TLR96 requires a TLR50 (purchased separately) for
connection to TLR Series Trac.
* The total number of cable suspension kits per section of trac
must be as follows:
-2’ (TLR2) and 4’ (TLR4) require 2 pendant-mounting kits per
section of trac.
-6’ (TLR6) and 8’ (TLR8) require 3 pendant-mounting kits per
section of trac.
1.
Remove the TLR50 cover and terminal block as outlined in the
TLR50 instructions.
2.
Pass the tandem cord through the TLR50 mounting plate and
through the slot in the strain relief bracket (supplied with TLR96) as
shown in figure 5.
3.
Bend tandem cord towards front of plate. Adjust position of
wire until the factory stripped end lines up with the corresponding
marks on the plate.
4.
Bend tandem cord around the strain relief bracket so they
straddle the bracket as shown in figure 6.
5.
Connect the TLR50 terminal block to the end of the tandem
cord and connect terminal block to mounting plate outlined in
the TLR50 instructions
6.
Pass the end of the cable without the ball through the hole in
the cable stop bushing as shown in figure 3 (connection to trac).
Thread the cable stop bushing into the sliding bushing and slide
to desired location on track (note: the small plastic grommet in
the TLR series trac (used for flush mount applications) can be
pushed out of the way by hand if it interferes with the sliding
bushing).
7.
Connect the TLR50 to the trac and fasten TLR50 cover as
outlined in the TLR50 instructions.
8.
Remove strap from canopy by removing the 2 screws, and set
strap aside. Insert the end of the cable through the center hole
in the cable adjuster (installed in the canopy). While holding the
canopy in place by hand, adjust the cable to desired height by
either pulling on the extra cable from the back side of the cable
adjuster to raise, or depressing the center sleeve on the cable
adjuster and pulling cable away from canopy to lower. The
cable can be trimmed once final position is obtained.
9.
Insert tandem cord through slot in canopy. Place fiber washer
over tandem cord, followed by the strain relief clamp. Route
wires along the cable with the enclosed wire ties. When cable is
in the intended position, tighten strain relief clamp until snug (see
figure 7). Trim tandem cord wires minimum 6” from the backside
of the canopy.
10.
Make electrical connection to the transformer secondary
wires in the junction box in accordance with Local & National
Electric Codes.
11.
Install the strap to the junction box with the 2 junction box
screws (not supplied). (strap is compatible with 3 1/4” & 4”
octagon / round j-box, plaster ring j-box covers, handy boxes &
switch boxes).
12.
Line up the canopy holes with the tapped holes in the strap.
Hold in place while securing the canopy with the 2 screws
removed in step 8.
Figure 5
Figure6
Figure 7
Cable Adjuster
Canopy
Cable
Strain Relief Clamp
Tandem Cord
Fiber Washer
Tandem Cord
Strain Relief Bracket
Strain Relief Bracket
Tandem Cord
TLR50 Mounting Plate
TLR50 Mounting Plate